Field Accuracy Objectives Accuracy in the field is assessed through the adherence to all
field instrument calibration procedures, sample handling, preservation, and holding time
requirements. Accuracy will also be evaluated through the use of field/trip blanks, field
spikes, and cooler temperature blanks. Field/trip blanks will be collected at a frequency
of one per day for each analytical parameter. Field/trip blanks will be used to assess any
contamination attributable to shipment and transportation and/or on-site storage of
samples and sample media. These blanks will be selected from the media provided for the
sampling events by the off-site laboratories and as such the blanks will represent actual
field samples with the sole exception that no air will be drawn through them. Analysis of
field/trip blanks for silica and asbestos will only occur if these analytes are detected in
samples. In addition, during the background phase of the program, the accuracy of the
mercury sampling and analysis method will be tested. Ambient air samples will be
collected at one location using a series of four carbon traps prespiked (50 ng/trap) with
mercury. These samples will provide data on the accuracy of the method under actual
field sampling condition. Following the background phase, one field spike will be
performed every other week.
Laboratory Accuracy Objectives Laboratories assess the overall accuracy of their
instruments and analytical methods (independent of sample or matrix effects) through the
measurement of “standards”, materials of accepted reference value. Accuracy will vary
from analysis to analysis because of individual sample and matrix effects. In an
individual analysis, accuracy will be measured in terms of method blank results,
processing blank results, the percent recovery (%R) of surrogate or internal standard
compounds, standard reference materials (SRMs) and/or laboratory control
samples (LCSs) and LCS Duplicates. This gives an indication of expected recoveiy for
analytes tending to behave chemically like the spiked or surrogate compounds and
provides a measure of bias for the parameter of interest. Accuracy control limits are
provided in Tables 8-2 through 8-10. The laboratory method blanks will indicate any
adverse effects of sample contamination from an outside source (i.e., sample preparation
or sample analysis) and could result in a positive bias. The frequency of surrogates or
internal standards, SRMs, LCSs, LCS Duplicates are defined in Tables 8-2 through 8-10.
Laboratory accuracy will be improved by following the EPA and NIOSH methods which
include detailed requirements for each analysis, utilizing experienced/trained laboratory
personnel, ensuring the purity of all chemicals, and conducting laboratory
audits. Accuracy of the silica analysis will be improved by an initial collection of a dust
sample from the site. The dust sample will be collected on each floor of the building,
homogenized by the laboratory, and analyzed for silica. This will be the site-specific
standard used by the laboratory for the remainder of the program and will serve the
following two purposes:
• Will identify the phases of silica potentially present in the air
• Will show interferences that may require the use of secondary and/or tertiary
peaks for silica phase quantitation
8.2.3 Representativeness