Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - February 1, 2006

Field Accuracy Objectives Accuracy in the field is assessed through the adherence to all field instrument calibration procedures, sample handling, preservation, and holding time requirements. Accuracy will also be evaluated through the use of field/trip blanks, field spikes, and cooler temperature blanks. Field/trip blanks will be collected at a frequency of one per day for each analytical parameter. Field/trip blanks will be used to assess any contamination attributable to shipment and transportation and/or on-site storage of samples and sample media. These blanks will be selected from the media provided for the sampling events by the off-site laboratories and as such the blanks will represent actual field samples with the sole exception that no air will be drawn through them. Analysis of field/trip blanks for silica and asbestos will only occur if these analytes are detected in samples. In addition, during the background phase of the program, the accuracy of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the accuracy of the method under actual field sampling condition. Following the background phase, one field spike will be performed every other week.

Laboratory Accuracy Objectives Laboratories assess the overall accuracy of their instruments and analytical methods (independent of sample or matrix effects) through the measurement of “standards”, materials of accepted reference value. Accuracy will vary from analysis to analysis because of individual sample and matrix effects. In an individual analysis, accuracy will be measured in terms of method blank results, processing blank results, the percent recovery (%R) of surrogate or internal standard compounds, standard reference materials (SRMs) and/or laboratory control samples (LCSs) and LCS Duplicates. This gives an indication of expected recoveiy for analytes tending to behave chemically like the spiked or surrogate compounds and provides a measure of bias for the parameter of interest. Accuracy control limits are provided in Tables 8-2 through 8-10. The laboratory method blanks will indicate any adverse effects of sample contamination from an outside source (i.e., sample preparation or sample analysis) and could result in a positive bias. The frequency of surrogates or internal standards, SRMs, LCSs, LCS Duplicates are defined in Tables 8-2 through 8-10. Laboratory accuracy will be improved by following the EPA and NIOSH methods which include detailed requirements for each analysis, utilizing experienced/trained laboratory personnel, ensuring the purity of all chemicals, and conducting laboratory audits. Accuracy of the silica analysis will be improved by an initial collection of a dust sample from the site. The dust sample will be collected on each floor of the building, homogenized by the laboratory, and analyzed for silica. This will be the site-specific standard used by the laboratory for the remainder of the program and will serve the following two purposes:

• Will identify the phases of silica potentially present in the air • Will show interferences that may require the use of secondary and/or tertiary peaks for silica phase quantitation

8.2.3 Representativeness

55

CITY_DEP_WORBY_CANNATA_SUBP_000094617

NYC-WTC_000427469

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427469Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000424476

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000426957

Plan for environmental community air monitoring at 133-135 Greenwich & 21-23 Thames, Sept 2005.

Similar indexed content

NYC-WTC_000425068

Title and approval sheet for Environmental Community Air Monitoring Program and plan at Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000426688

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →