Ambient Air Monitoring Program QA Plan, 130 Liberty

Machine-extracted title · confidence 42%

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

NYC-WTC_000426556–000426687
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■< Z ■<

o o io Ambient Air Monitoring Program Quality Assurance Project Plan 130 Liberty Street - NY, NY Section No. 8 Revision No.: 0 Date: September 7, 2005 co

I Lower Manhattan Development Corporation Page 52 of 124 ■D c o o CT o o' bj ■D CD o CD O 3. 00 03 Table8-8^Measur^ment^erformanceCriteriaTable-A^bestosJwTEM/SE^^ o QC Sample or Activity DQI o Frequency Measurement Performance Criteria Corrective Action o c Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, and/or Precision-Overall 3 samples are > 5x QL qualify data. CD D *No situation where one result is detected at > 5x QL and other result is not detected Standard Reference Materials 1/year Percent recoveries 80-110% Recalibrate, reanalyze, and/or Accuracy/Bias qualify data. Intra-analyst QC 1/50 samples < 5 structures: + 1 structure Recalibrate, reanalyze, and/or Precision 5-20 structures: +2 structures qualify data. > 20 structures: -I- 3 structures Inter-analyst QC 1/25 samples < 5 structures: + 1 structure Recalibrate, reanalyze, and/or Precision 5-20 structures: +2 structures qualify data. > 20 structures: + 3 structures Method Blanks 1/batch <53 structures/mm* in blank Locate source of contamination and Accuracy/Bias - < 18 structures/mm* in cumulative average correct before analysis can proceed. Contamination Field/Trip Blanks l/day^“’ Arithmetic mean of 3 field blanks must be Retest, reanalyze, and/or qualify Accuracy/Bias - < 70 S/mm" data. Contamination Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness Refer to Section 11.1.2.3 for procedures to be used for measuring structures and fibers. o ®Only analyzed if asbestos is detected in the associated samples. Reanalyze: refers to reanalysis of same sample.

o m

o J] □0

s >

c □0 o o o o CD CD 00 ID

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000426608Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000423219

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

Similar indexed content

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →