NYC-WTC_000421972
QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.
79 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗QA plan reference for deconstruction ambient air monitoring, Sept 2005.
NYC-WTC_000426821–000426952OCR status: ok · source: pdftotext
z ■< Z ■<
o o io Ambient Air Monitoring Program Quality Assurance Project Plan 130 Liberty Street - NY, NY Section No. 8 Revision No.: 0 Date: September 7, 2005 co
I Lower Manhattan Development Corporation Page 52 of 124 ■D c o o CT o o' bj ■D CD o 00 3. o 03 Table8-8^Measur^ment^erformanceCriteriaTable-A^bestosJwTEM/SE^^ o QC Sample or Activity DQI o Frequency Measurement Performance Criteria Corrective Action o c Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, and/or Precision-Overall 3 samples are > 5x QL qualify data. CD O *No situation where one result is detected at > 5x QL and other result is not detected Standard Reference Materials 1/year Percent recoveries 80-110% Recalibrate, reanalyze, and/or Accuracy/Bias qualify data. Intra-analyst QC 1/50 samples < 5 structures: + 1 structure Recalibrate, reanalyze, and/or Precision 5-20 structures: +2 structures qualify data. > 20 structures: -I- 3 structures Inter-analyst QC 1/25 samples < 5 structures: + 1 structure Recalibrate, reanalyze, and/or Precision 5-20 structures: +2 structures qualify data. > 20 structures: + 3 structures Method Blanks 1/batch <53 structures/mm* in blank Locate source of contamination and Accuracy/Bias - < 18 structures/mm* in cumulative average correct before analysis can proceed. Contamination Field/Trip Blanks l/day^“’ Arithmetic mean of 3 field blanks must be Retest, reanalyze, and/or qualify Accuracy/Bias - < 70 S/mm" data. Contamination Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness Refer to Section 11.1.2.3 for procedures to be used for measuring structures and fibers. o ®Only analyzed if asbestos is detected in the associated samples. Reanalyze: refers to reanalysis of same sample.
o m
o J] □0
s >
c □0 o o o o CD ID 00 CO
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000421972
QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.
79 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423219
Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.
79 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000422676
QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.
79 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426556
Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.
79 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421711
Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.
77 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421577
QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.
75 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427221
Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.
72 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447031
QA plan document for ambient air monitoring program for Liberty Street deconstruction.
79 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447891
QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.
79 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449908
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.
79 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443239
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.
79 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448520
Quality assurance plan for ambient air monitoring during deconstruction at Liberty Street.
79 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.
Similar indexed content
Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.
Similar indexed content
QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.
Similar indexed content
Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.
Similar indexed content
Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.
Similar indexed content