Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

Mercury (Gaseous) Using a Direct Read Analyzer

Table 13-lb summarizes the inspection, testing, and maintenance activities associated with the gaseous mercury analysis using the Ohio Lumex RA915+ mercury analyzer._______________ Table 13-lb. Maintenance, Testing, and Inspection Requirements for the Ohio Lumex RA915 + Mercury Analyzer Fault Symptom Possible Cause Corrective Action Segments of the indicator -Power cable is out of order -Repair the power cable table on the display and control unit are not -Display unit cable is out of -Repair the display unit highlighted when the order analyzer is switched on. -Battery is discharged -Charge the battery The (*) symbol at the -Battery is discharged -Charge the battery display and control panel is not dimmed out when the “Lamp ignition” button is pressed:

-if the optical switch is in -Operation is possible only -Set the optical switch into positions II position I with attachments or III

-if the optical switch is in -The single-pass cell is -Remove the single-path cell, check if position II contaminated, compartment the compartment windows are clean, windows are contaminated or make sure that there are no foreign foreign objects are found in the objects inside the compartment compartment -Clean the multi-path cell (see -if the political switch is in -Multi-path cell is appropriate section) position III contaminated______________ The battery discharge The battery is fully discharged Charge the battery indicator________________ Fault Symptom Possible Cause Corrective Action Red (glows for some time and then goes out when the aiialyzeiJ^jwitehed oii^ In the TEST mode, relative -Special lamp is not switched -Press the “Lamp ignition” button deviation R of the measured on -Set the switch of the test cell to the test number differs from the -The test cell switch is in idle working position tabulated value by more position -Shake the test cell 2-3 times by the than 25%. -The test cell is out of order TEST (ON/OFF) switch -The absorption filter has failed -Replace the filter

86

CITY_DEP_WORBY_CANNATA_SUBP_000091558

NYC-WTC_000426433

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000426433Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →