NYC-WTC_000428658
Airborne asbestos exceedance at AFD Exhaust; concentration 88.2 s/mm3; March 14, 2005.
5 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Airborne asbestos exceedance at AFD Exhaust; concentration 88.2 s/mm3; March 14, 2005.
NYC-WTC_000426084
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
RJ LeeGrowp, Inc. Exceedance Report Date of Exceedance: March 14, 2005 Analyte: Airborne Asbestos Location: (South) AFD Exhaust. Carlisle Street Sidewalk Bridge Concentration: 88.2 s/mm^ Trigger Level: 70 s/mm^
Summary of Event:
On Monday, March 14, 2005 sampling for airborne asbestos fibers was conducted at the (South) AFD Exhaust at the Carlisle Street Sidewalk Bridge location outside the 4 Albany Street Building. The sampling was initiated at 2:47PM on March 14, 2005 and concluded at 10:47PM that same day (total collection time: 480 min.; sample volume: 2400 liters). The sample was received at the RJ Lee Group laboratory (Monroeville, PA) on Wednesday, March 16 and analyzed that evening using the AHERA TEM method. The results from the analysis of the sample reported an asbestos fiber concentration of 88.2 s/mnf.
The exceedance was reported by the laboratory via telephone to Mike Campbell on Wednesday night and the results were e-mailed to all parties immediately. The DEP and EPA were notified, via telephone, of the exceedance on the morning of Thursday, March 17 and a conference call to discuss the exceedance was held at 12:30PM that afternoon.
Corrective Action: The air filtration device (AFD) that had the exceedance was located on the Sth floor. During the 2““’ shift on Monday, March 14, the shift of the exceedance, there was no work performed on this floor other than regular filter maintenance of the AFD’s. Regular filter maintenance involves replacing the pre-filter and visual inspection of the secondary filter. If at the time of the routine maintenance the secondary filter is visually dirty, it is replaced. During the routine filter maintenance of the AFD in question, the secondary filter was visually observed to be acceptable and therefore was not replaced.
Upon notification of the exceedance this AFD was immediately shut down, the intake was sealed with poly and the slinky hose was taped shut and the spare AFD oir the 8*^ floor was initialized. Since all abatement and final cleaning activities had previously been completed on this floor and encapsulation of the floor had taken place only hours before the report of the exceedance, there was no work stoppage.
Subsequent investigation of the exceedance included a visual inspection of the AFD, a review of PAL’s (the abatement contractor) site log along, and interviews of the site management team. Visual inspection of the AFD showed duct tape repairs and a stretched, uncoiled, section of the “slinky” exhaust hose. The HEPA filter appeared to be seated properly. The PAL site log did not have any information regarding this AFD during the shift in question, however PAL representatives stated that during routine filter maintenance a breech in the “slinky” hose was found and a repair, utilizing spray glue and duct tape was perfoimed. This repair reportedly required the AFD to be shut dowir for approximately 10 minutes.
No definite cause of the exceedance has been identified, other than the reference to the slinky exhaust hose repair reported, to have occurred during the sampling time frame of this exceedance.
Attachments: Report summary - AHERA TEM Ah Results for March 14, 2005 Figures - Air sampling maps of asbestos TEM locations for March 14, 2005
Submitted By: Mike Campbell Date: March 22, 2005 Final
CITY_DEP_WORBY_CANNATA_SUBP_000090398
NYC-WTC_000426084
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000428658
Airborne asbestos exceedance at AFD Exhaust; concentration 88.2 s/mm3; March 14, 2005.
5 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448654
Air sampling exceedance for asbestos fibers outside 4 Albany Street; results and notifications.
4 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450386
Exceedance notice for airborne asbestos fibers from AFD exhaust at 4 Albany Street; March 14, 2005 event.
4 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425961
Final TEM air analysis report for AFD exhaust, February 26, 2005 exceedance.
3 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425238
Exceedance summary and air sampling results for asbestos at LMDC site; investigation started.
3 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000428764
Airborne asbestos sampling summary at AFD Exhaust; exceedance noted Feb 26, 2005.
3 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426148
Summary of asbestos air exceedance event with TEM analysis and HEPA device observations.
3 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234319
Lab report documenting an airborne asbestos fiber concentration exceedance at the AFD Exhaust BL6 location on February 26, 2005.
3 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444129
Lab report documenting an airborne asbestos fiber concentration exceedance at the AFD Exhaust BL6 location on February 26, 2005.
3 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451069
Report documents an asbestos fiber concentration exceedance at the basement AFD Exhaust location on February 26, 2005.
3 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000233245
Report documents an asbestos fiber concentration exceedance at the basement AFD Exhaust location on February 26, 2005.
3 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425904
Exceedance report for airborne asbestos at South AFD Exhaust, March 14, 2005.
3 shared non-person entities · similarity 0.920
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000428658
Airborne asbestos exceedance at AFD Exhaust; concentration 88.2 s/mm3; March 14, 2005.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450386
Exceedance notice for airborne asbestos fibers from AFD exhaust at 4 Albany Street; March 14, 2005 event.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448654
Air sampling exceedance for asbestos fibers outside 4 Albany Street; results and notifications.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452514
Exceedance of asbestos fibers detected during sampling at the South AED Exhaust, March 2005.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438371
Exceedance event summary for airborne asbestos at AED exhaust site, March 14, 2005.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425904
Exceedance report for airborne asbestos at South AFD Exhaust, March 14, 2005.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Airborne asbestos exceedance at AFD Exhaust; concentration 88.2 s/mm3; March 14, 2005.
Similar indexed content
NYC-WTC_000448654
Air sampling exceedance for asbestos fibers outside 4 Albany Street; results and notifications.
Similar indexed content
NYC-WTC_000450386
Exceedance notice for airborne asbestos fibers from AFD exhaust at 4 Albany Street; March 14, 2005 event.
Similar indexed content
Final TEM air analysis report for AFD exhaust, February 26, 2005 exceedance.
Similar indexed content
NYC-WTC_000425238
Exceedance summary and air sampling results for asbestos at LMDC site; investigation started.
Similar indexed content