Part II - Environmental Community Monitoring Plan
133-135 Greenwich & 21-23 Thames Streets
Airtek Project 05-0701 - Rev 2 September 16, 2005
Precision # 5 Fg/m for cone. 80 ng/m3 40 CFR, Pt 50, Both PMIO values must be
Single analyzer 1/6 days App M, S 4.1 > 20 pg/m .
IVo for cone. >80 pg/m
Reporting 1/ 3 months 95% CI < ± 15% 40 CFR, Pt 58,
organization App A, S 5.3
EPA-600/4-83-023
Accuracy Transfer standards different
Single analyzer Quai'terly None 40 CFR, Pt 58, then those used in
Annual accuracy (all sites yearly) 95% CI # + 20% App A calibration. Recalibrate
EPA-600/4-83-023 quarterly (all sites before
Vol II, App 15, S 6 any additional sampling.
Invalidate data to last
acceptable flow yearly)
check if difference > 10%.
QC Checks
Field calibration flow I/month Percentage difference # ±7 40 CFR, Pt .50,
check from sampler's indicated App M, S 8.2 Trouble shoot and
flow rate or # ± 10 % from Vol II, MS 2.10.3 recalibrate sampler.
"Standard" filter at beginning of design condition flow rate
weighing weighing day
+ 20 g of original weight Vol II, S 2.10.4 Trouble shoot and reweigh.
Reweighing filters 5 exposed and 5
unexposed/day ± 20 g of original weight Trouble shoot and reweigh.
1/montli
± 2 g at 10 mg Vol II, S 2.10.4 Trouble shoot and reweigh.
Balance zero and every fifth filter- ± 4 g at zero
Calibration check ± 2 g at 10 mg Vol II, S 2.10.4