Asbestos Air Sampling Results NYC ER/NJ DEP
Date Sampiinq Sample PCM by NiOSH 7400 TEM (AHERA)
Sampled Sample No. Location Volume Matrix f/mm’ f/cc <5p >5p S/mm‘ S~f/cc*
S _____
10/2/2001 00341 Liberty Park 480 Air <7.0 <0.006 0 0 <6.16 <0.0049
10/2/2001 00342 ITGO Termin 480 Air <7.0 <0.006 0 0 <6.15 <0.0049
10/2/2001 00343 ■MC Termina 480 Air <7.0 <0.006 0 0 <6.16 <0.0049
10/2/2001 00344 shell Termina 480 Air <7.0 <0.006 0 0 <6.15 <0.0049
coc#04115
PCM: Phase Contrast Microscopy by NiOSH 7400
TEM: Transmission Electron Microscopy (TEM) EP.A 40CFR Par: 763 (AHERA). Sample volume is below recommended limit of the method.
‘Structure (S) roughly equivalent to Fiber (f)
Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mmT Volume 1200 L, for 25 mm filter (TEM)
Period in which samples were collected and retrived
Sampling Location Sampling Times
Liberty Park 1250 (10/02/01) -2050 (10/02/01)
CITGO Terminal 1350 (10/02/01)-2150 0 0/02/01) ERT: 10/05/01 09:50 AM
FMC Terminal 1425 (10/02/01) - 2225 (10/02/01)
Shell Terminal 1445 (10/02/01) - 2245 (10/02/01)