Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

PCDDs/PCDFs and PAHs Using a Tisch PUF High Volume Sampler

Table 13-lc summarizes the maintenance, testing, and inspection activities for the Tisch PUF samplers.

Table 13-lc. Maintenance, Testing, and Inspection Requirements for Tisch PUF Sampler Used for PCDDs/PCDFs, PAHs and PCBs Equipment Frequency Method Acceptance Corrective Action Criteria Tisch PUF sampler Single point flow- Within =20% of the Service Tisch PUF check at normal flow rate indicated sampler and perform operating flow rate by the Tisch PUF a new multi-point on weekly basis sampler calibration. Power Cords Check for crimps or No obvious damage Replace as cracks necessary Cartridge Assembly Visually check on No obvious deposits Wipe clean daily sample recovery days Gaskets At 3 month No leaks or Replace as intervals, inspect all compression necessary gaskets in the damage evident sampler Brushes Replace after 600- Stable flow rate Replace as 1000 hrs. of necessary operations

Motor Replace as needed Consult Obtain the correct manufacturer for model correct model of motor Tubing and fittings Visually inspect on No crimps, cracks, Replace as necessary sample recovery or obstructions: no days crossthreading

91

CITY_DEP_WORBY_CANNATA_SUBP_000078129

NYC-WTC_000425158

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000425158Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426957

Plan for environmental community air monitoring at 133-135 Greenwich & 21-23 Thames, Sept 2005.

Similar indexed content

NYC-WTC_000424476

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000427415

CoC document detailing plan for Environmental Community Air Monitoring at Greenwich Street sites.

Similar indexed content

NYC-WTC_000426688

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →