NYC 9/11 Public Portal Document
Section 2 - Ambient Air Monitoring Program Revision No.: 0
130 Liberty Street Deconstruction Plan Date: September 7, 2005
Lower Manhattan Development Corporation
11.0 ELECTRONIC DATA MANAGEMENT AND REPORTING
11.1 Data Management
11.1.1 Real-Time Data
Real-time data (i.e., PMio and PM2.5) will be downloaded daily from data loggers using cellular
telephone modems on each monitor. Ten-minute averages from each station will be transmitted
to a central station. Daily plots of real-time data will be generated. Twenty-four hour averages
of PMio and PM2.5 will be calculated using these data and included on the daily summaries
posted on the LMDC website. Graphical presentation of PMio and PM2.5 data will be provided
on a weekly basis. The gaseous mercury results will be noted on a form during the collection of
data. These results will be hand-entered into the central station and included on the daily
summaries posted on the LMDC website. The data from the meteorological station units will be
recorded on a dedicated data logger, and telemetered back via cellular modems to the central
computer.
11.1.2 Fixed Laboratory Data
Laboratory data will be received as hard copy and electronic data deliverables (EDD). EDDs
associated with fixed laboratory analyses will be in Excel format. A spreadsheet will be
provided to each laboratory for completion and to allow easy compilation of the data by TRC
from all laboratories. The spreadsheet will provide results of the target parameters compared to
the Target Air Quality Levels, 3x the Target Air Quality Levels, and the USEPA Site-Specific
Trigger Levels. The laboratory will calculate all results using sample volumes provided by the
Environmental Consultant.
A cumulative average will be generated after the first week of sampling. Results will
subsequently be compared and rolled into this cumulative average. Daily summaries of all
results will be posed on the LMDC’s website.
The spreadsheets associated with dioxin/furan results will include speciated results for each
dioxin/furan congener, the TEEs used, and the TEQ. The spreadsheets associated with PAH
results will include speciated results for each target PAH, the BAP-factors used, and the BAP-
equivalent concentration. The spreadsheets associated with PCB results will include the results
for individual Aroclors as well as the result for total PCBs.
Authorized personnel from USEPA Region 2, NYCDEC, NYSDEC and NYSDOL will also be
provided direct access to the website where all air monitoring data will be posted. In addition,
once the air monitoring data has been subject to QA/QC review validated results will also be
posted on the website in a dedicated location for direct access by the general public.
11-1
CITY_DEP_WORBY_CANNATA_SUBP_000075904
NYC-WTC_000424737
OCR can misread numbers and units. Confirm readings against the page image before using them.