NYC 9/11 Public Portal Document
Section 2 - Ambient Air Monitoring Program Revision No.: 0
130 Liberty Street Deconstruction Plan Date: September 7, 2005
Lower Manhattan Development Corporation
5.7.2 PCBs
Each site will have one (1) SKC Leland Legacy pump equipped with a glass cylinder containing
a PUE plug. Samples will be collected at a flow rate of five liters per minute with a sampling
period of approximately 24 hours for a resulting total air volume of 7.2 m\
5.8 Visible Emissions
Visible emissions during the deconsti-uction project will be monitored as follows:
Abatement Phase
During each work shift, the Environmental Consultant will be tasked with observing the
Building’s containment barriers and exterior. Special attention will be paid to established
isolation barriers and area(s) of high emission potential to identify any visible emissions.
If any visible emission is noted exterior of the work area, the work will be stopped and an
immediate evaluation of in-place engineering controls for the emission location will take
place. The evaluation may include, but is not limited to, work activities and smoke
testing of the isolation barriers. Any damaged or malfunctioning engineering control will
be repaired immediately. The work will not be restarted until engineering controls are
repaired or determined to be functioning properly.
Deconstruction Phase
During each work shift, the Environmental Consultant will observe deconstruction
operations to monitor visible dust in the air and suppression measures being applied by
the deconstruction contractor. The Environmental Consultant may, depending on the
severity and duration of dust condition, order a stoppage of the work or require modified
work practices to reduce visible dust.
Notification
The EPA Region 2 office and NYCDEP will be notified promptly of any visible
emissions observed to cross the property line of the Building, as well as promptly advised
of the corrective actions taken.
5-5
CITY_DEP_WORBY_CANNATA_SUBP_000075888
NYC-WTC_000424721
OCR can misread numbers and units. Confirm readings against the page image before using them.