NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

CoC: Environmental Community Air Monitoring Plan

Machine-extracted title · confidence 52%

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

NYC-WTC_000424323–000424451
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

results of the PCB Aroclor QC measurements (Tabic 8-4) demonstrate adequate accuracy and precision of the sample extract analysis.

11.2 Analytical Quality Control

Tables 8-2 through 8-10 summarize the QC procedures checks, and samples, and their respective acceptance limits for each fixed laboratory analytical parameter that will be used during the project.

11.2.1 Field Analytical QC

Calibration procedures discussed in Section 13.2.1 will be adhered to for field analyses of gaseous mercury in order to ensure the accuracy of sample measurements.

11.2.2 Fixed Laboratory QC

All required QC checks and QC samples and the associated QC acceptance limits are detailed in the associated methods and in Tables 8-2 through 8-10.

11.2.2.1 Method Blanks/Preparation Blanks Method blanks will be performed as part of each analytical batch for each methodology performed. Method blanks are used to evaluate contamination introduced during sample preparation and/or analysis by the laboratory.

11.2.2.2 Instrument Blanks Instrument blanks are used to evaluate contamination resulting from the analytical reagents and the instrumentation. In addition, instrument blanks are sometimes used to assess potential carryover after the analysis of a highly contaminated sample. Instrument blanks are only required for select analytical parameters.

11.2.2.3 Surrogate Spikes Surrogate spikes arc used to evaluate extraction efficiency or analytical bias on a sample by sample basis for organic parameters. Surrogate spikes are added to all samples for organic parameters. Surrogate spikes are another measure of sample-specific QC.

11.2.2.4 Laboratory Control Samples Laboratory control samples (LCSs) and LCS Duplicates are used to evaluate almost all parameters for the ability of the laboratory to accurately and precisely identify and quantitate target compounds in a reference matrix when spiked at the mid range of the calibration curve at a known concentration using a secondary source standard. LCSs and/or LCS Duplicates are typically performed as part of each analytical batch for each methodology with the exception of asbestos, PMio, PM2.5, ignitability and corrosivity,

11.2.2.5 Laboratory Duplicate Laboratory duplicates are used to evaluate laboratory preparation and analysis precision. These analyses are typically performed for inorganic

73

CITY_DEP_WORBY_CANNATA_SUBP_000072613

NYC-WTC_000424395

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424395Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →