Method Blanks 1/batch Silica < Reclean, Accuracy/Bias-
detection limit reanalyze Contamination
and/or qualify
data
Field/Trip 1/day Silica < Reclean, Accuracy/Bias-
Blanks detection limit reanalyze Contamination
and/or qualify
data
Data NA Field 80%; NA Data
Completeness Laboratory Completeness
Check 95%
Laboratory 1/day Percent Recalibrate, Accuracy/Bias
Control recoveries 80- reanalyze
Standards 120% and/or qualify
Sample 10% of samples RPD < 100 Recalibrate, Precision
Reanalysis reanalyze
and/or qualify
Only analyze if silica is delected in the associated samples.
Reanalyze: refers to reanalysis of same sample.
rab/e 8-8. Measurement Performance Cn'teria Tab/e-Asbestos by TEM^SEM
QC Sample or Frequency Measurement Corrective DQI
Activity Performance Action
Criteria
Field 1/week *RPD < 40 Assess Precision-
Duplicates when positive laboratory Overall
results for both precision; and
samples are > /or qualify
5x QL data.
*No situation
where one
result is
detected at >
5x QL and
other result is
not detected
Standard 1/year Percent Recalibrate, Accuracy/Bias-
Reference recoveries 80- reanalyze
Materials 110% and/or qualify
Intra-Analyst 1/50 samples < 5 structures: Recalibrate, Precision
47