NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
data.
Field/Trip 1/day Absolute value Reclean Accuracy/Bias-
Blanks of target metal reanalyze, Contamination
must be < QL and/or qualify
data.
Quartz Fiber 1 /batch Absolute value Obtain new lot Accuracy/Bias-
Filter Media of target metal of media. Contamination
Cleaning must be < QL
Verification
Check
Internal Every sample, Samples: 30- Dilute sample Accuracy/Bias
Standards blanks, QC 130% of IS 5x, add IS and
calibration reanalyze,
blank and/or qualify
Calibration data.
Standards: 80-
120% of IS in
calibration
blank
Instrument Daily, prior to Mass resolution Retune Accuracy/Bias
Tune calibration and <1.0 amu at instrument,
sample analysis 10% peak repeat tune
height and mass solution and
calibration ± analysis
0.1 amu from
the expected
value
Data NA Field 80%,. NA Data
Completeness Laboratory Completeness
Check 95%
Reanalyze: refers to reanalysis of same digestated or QC sample.
Tab/e 8-3. Messurement Performance Critena Tab/e-PAHs by GC/MS-S/M
QC Sample or Frequency Measurement Corrective DQI
Activity Performance Action
Criteria
Field 1/Week *RPD < 40 Assess Precision-
Duplicates when positive laboratory Overall
results for both precision; and
samples are > /or qualify data.
5x QL
*No situation
where one
result is
40
CITY_DEP_WORBY_CANNATA_SUBP_000072580
NYC-WTC_000424362