The RPD between the LCS and LCS duplicate or sample and sample duplicate, is
calculated to compare to precision objectives. LCS/LCS duplicates and laboratory
duplicates will be used to assess analytical precision and the field duplicates will be
used to assess project precision. The RPD will be calculated according to the
following formula:
5? pn - If! 1- ! I1 2)
0.5 (Afiofjst !!i Ssaipfe 2)
The impact of analytical imprecision, project imprecision, and overall imprecision
(when both analytical and project precision tests show problems) on data usability
will be assessed. If the precision results yield data which are not usable, the Data
Validation memoranda will identify how this problem will be resolved.
16.2.2 Accuracy
If field or laboratory contamination exists, the impact on the data will be evaluated
during the data usability assessment. The direction of bias for contamination will be
identified. Accuracy is assessed by determining percent recoveries (%Rs) for
surrogate/intemal standard compounds added to each field and QC sample to be
analyzed for organic parameters. Accuracy for all analyses will be further assessed
through determination of %Rs for LCSs, SRMs, field spikes, and calibration results,
etc. If the Data Validation memoranda indicate contamination and/or analytical
biases, the impact on the data will be assessed. %R for LCSs, SRMs, field spikes, and
surrogate compound results will be determined according to the following equation:
Ci?Hi’s.t;raw.Sas
Overall contamination and accuracy/bias will be reviewed for each analytical
parameter. The data usability assessment will include any limitations on the use of the
data, if it is limited to a particular data set, parameter, or laboratory. If the accuracy
results yield data which are not usable, the Data Validation memoranda will identify
how this problem will be resolved.
16.2.3 Representativeness
If field duplicates indicate spatial variability, the data usability assessment will
evaluate the impact on the data. Overall sample representativeness will be evaluated
for each analytical parameter. The data usability assessment will include any
limitations on the use of the data, if limited to a particular, data set, parameter, or
laboratory. If the results of the evaluation of representativeness yield data which are
not usable, the Data Validation memoranda will identify how this problem will be
resolved.