NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
information related to analysis will be documented in controlled laboratory
logbooks, instrument printouts, or other approved forms. All entries that are not
generated by an automated data system will be made neatly and legibly in permanent,
waterproof ink. Information will not be erased or obliterated. Corrections will be
made by drawing a single line through the error and entering the correct information
adjacent to the cross-out. All changes will be initialed, dated, and, if appropriate,
accompanied by a brief explanation. Unused pages or portions of pages will be
crossed out to prevent future data entry. Laboratory records will be reviewed by
the Laboratory Section Leaders on a regular basis, and by the Laboratory QA
Manager periodically, to verify adherence to documentation requirements.
J4.4.2.2 Electronic Deliverables
Laboratory data will be received as hard copy and electronic data deliverables
(EDD). EDDs associated with fixed laboratory analyses will be in Excel format. A
copy of the required EDD format is provided in Attachment E. A spreadsheet will be
generated using the EDDs to provide results of the target parameters compared to the
Target Air Quality Levels, 3x the Target Air Quality Levels, and the USEPA Site-
Specific Trigger Levels. The laboratory will calculate all results using sample
volumes provided by AIRTEK. A rolling average will be generated after the first
week of sampling. Results will subsequently be compared and rolled into this
average. The EDDs associated with dioxin/furan results will include speciated results
for each dioxin fiiran congener, the TEFs used, and the TEQ. The EDDs associated
with PAH results will include speciated results for each target PAH, the BAP-factors
used, and the BAP-equivalent concentration. The EDDs associated with PCB results
will include the results for individual Aroclors as well as the result for total PCBs.
14.5 Data Handling and Management
14.5.1 Data Entry and Verification
All data entry performed by AIRTEK or its contractors will be proofed 100% for
accuracy. Verification will be carried out either by proofing a printout against the
original data or by duplicate entry and comparison of the two data sets to detect
discrepancies.
14.5.2 Data Transformation and Reduction
14.5.2.1 Dioxins/Furans Transformation and Reduction
The laboratory will be responsible for calculating the toxicity equivalent quotient
(TEQ) for each sample. The TEQ will be calculated using toxicity equivalency
factors (TEFs) from Interim Procedures for Estimating Risks Associated With
Exposure to Mixtures of Chlorinated Dibenzop- Dioxin and Dibenzofurans (CDDs/
CDFs), EPA-625/3-89-016, March 1989. Each dioxin or furan congener is multiplied
107
CITY_DEP_WORBY_CANNATA_SUBP_000072647
NYC-WTC_000424429
OCR can misread numbers and units. Confirm readings against the page image before using them.