CoC: Environmental Community Air Monitoring Plan

Machine-extracted title · confidence 52%

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

NYC-WTC_000424323–000424451
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

TABLE 13.4b Summary of Calibration Procedures for Fixed Laboratory Analyses Waste Sample Analysis - VOC, SVOC, Pesticides/Herbicides/PCB, Metals/ Mercury, pH Instrument Activity Frequency Acceptance Corrective SOP Criteria Action Ref. *

GCMSSVOCOl 17 DFTPP Tuning Every 12 hours SW846-8270C criteria Retune, rerun for 00 GC/MS hiitial cal. (5 stds) As needed CCCs <30%RSD, SPCCs > DFTPP criteria Semi­ Revision 1.4 method blank 1/20 per matrix 0.05 Rf; RSD avg.< 15% Recalibrate Volatiles No targets found Cont. cahbration every 12 hows Re extract mblk CCCs @ <25%D; SPCCs> Reran or recal/rerun all Surrogate stds. ALL 0.05Rf afftected samples Laboratory 1/20 permatri.x Withm Lab control limits Re-extract Control 1/20 per matrix Within Lab control limits Reclibrate/ rerwi all MS/MSD ALL samples Internal Standards -50 to +100% of 12 hour cal Reextract & rerun chk std. Rerun affected samples, dilute if matrix is issue

Hgl20998 Initial cal. (5 stds) As needed 0.995 Corr. Coeff. Recalibrate system Mercury/CV Revision 1.1 method blank Every 20 samples Not detected Rerwi affected samples AA Cont. calibration Every 10 samples +/- 20% Reran affected samples Spike and Dup 1/20 samples Spike +/- 25%, Dup -/- 20% at Reran spike/dup unless levels >5x Reporting Limit proven matrix Mfgs. Specs. interference

LCS 1/20 samples Rerun all affected samples Recalibrate ICP system ICP031195 Initial calibration As needed +/- 10% ICP metals Rcrwi affected samples Revision 1.2 Cont. calibration Every 10 samples +/- 10% Reran or qualify Calibration blanks Every 10 samples Not detected (<IDL) affected samples Calibrate with On use +- 0.05 Wilts Recalibrate, if still > SOPWCpH Corrosivity/ pH=7, and pH=4 0.05 replace probe 010596 Rev.l.6 buffers pH

100

CITY_DEP_WORBY_CANNATA_SUBP_000072640

NYC-WTC_000424422

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424422Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →