RJ LeeGroup, Inc. 350 Hochberg Road, Monroeville, PA 15146 Phone: (724) 325-1776 Fax: (724) 733-1799

Final Laboratory Report TEM Air Analysis RJ Lee Group, Inc. Report Date: 3/19/2005 350 Hochberg Road Sample Receipt Date: 3/19/2005 Monroeville, PA 15146 RJ Lee Group Job No.: TCN409139-25 USA Samples Received: 2 Method: Federal Register, 40 CFR, Part 763, October 30, 1987 Building: 4 Albany

Concentration

Date-Time Collected Filter Area Asbestos Analytical RJLG Sample Sample Start Area Volume Analyzed Structures Sensitivity Number Type Stop ■Sub Location I Comments- (mn?) (liter) (mirf) Chry Amph (S/mirf) (S/cc) 5248313.HT Area 3/18/2005 - 13:15:00 (SouthEast) - Clearance sampling 385 2970.00 0.13714 7 0 51.0 0.007 3/18/2005 - 18:45:00 for phase 3 abatement. Mezzanine. "7.3 oloof Location I.

5248314.HT Area 3/18/2005 - 13:15:00 (East) - Clearance sampling for 385 2945.00 0.13714 1 0 7.3 0.001 3/18/2005 - 18:25:00 phase 3 abatement. Mezzanine. '7.3 03)01 Location 2.

Authorized Signature: Uji Kimberly A. Allison, Manager - TEM Analysis /jeb

Notes; 1. Volumes provided by Deutsche Bank were used to calculate analytical results and sensitivities. 2. “<” indicates results less than analytical sensitivity. “—” indicates that sample was not analyzed. 3. Sample(s) for this project were analyzed at our: Monroeville, PA (NVLAP #101208-0, NY ELAP #10844) facility. 4. If RJ Lee Group, Inc. did not collect the samples analyzed, the verifiability of the laboratory's results are limited to the reported values. 5. Abbreviations: N/A-Not Applicable, Chry-Chrysotile Asbestos, Amph-Amphibole Asbestos, S-Stnictures. 6. Samples will be held for 90 days and then disposed of per Federal regulations. 7. These results are submitted pursuant to RJ Lee Group’s current terms and conditions of sale, including the company’s standard warranty and limitation of liability provisions. No responsibility or liabihty is assumed for the manner in which these results are used or interpreted.

Page 1 of 2

CITY_DEP_WORBY_CANNATA_SUBP_000072270

NYC-WTC_000424165

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424165Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000425751

Final TEM air analysis report for building 4, dated 3/19/2005.

Similar indexed content

NYC-WTC_000425941

Final TEM air analysis report for building 4, dated 3/19/2005.

Similar indexed content

NYC-WTC_000425765

Final TEM air analysis report for building 4, dated 3/19/2005.

Similar indexed content

NYC-WTC_000429028

Final TEM air analysis report for Building 4, 3/19/2005.

Similar indexed content

NYC-WTC_000427097

Final TEM air analysis report dated 3/19/2005 for building 4.

Similar indexed content

Compare copies and versions →