NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
16.2.3 Representativeness....................................................................................... 121
16.2.4 Sensitivity and Quantitation Limits........................................................... 121
16.2.5 Completeness.............................................................................................. 122
16.2.6 Data Limitations and Actions.................................................................... 122
17.0 REPORTING, DOCUMENTS, AND RECORDS................................... .. 124
Tables
Table 3-1. Distribution List.................................................................................... 10
Table 6-1. Target Air Quality Levels and USEPA Site-SpecificTrigger Levels ... 25
Table 7-la. Background Phase - Two Weeks (14 Consecutive Days)............... ... 33
Table 7-lb. Phase I: Preparation Phase & Asbestos and COPC Abatement and Removal.... 33
Table 7-lc. Phase II - Structural Deconstruction............................................................... 34
Table 7-2. Phase I: Preparation Phase & Asbestos and COPC Abatement and Removal
Sampling and Analysis Summary 35
Table 7-3. Phase II - Structural Deconstruction Phase Sampling and Analysis Summary ... 36
Table 8-1. Comparison of Laboratory Quantitation Limits with Project Action Levels...... 42
Table 8-2. Measurement Performance Criteria Table - Metals by ICP/MS.......................... 46
Table 8-3. Measurement Performance Criteria Table - PAHs by GC/MS-SIM.................... 47
Table 8-4. Measurement Performance Criteria Table - PCBs by GC/ECD.......................... 48
Table 8-5. Measurement Performance Criteria Table - PCDDs/PCDFs by HRGC/HRMS.. 49
Table 8-6. Measurement Performance Criteria Table - Mercury by CVAFS....................... 50
Table 8-7. Measurement Performance Criteria Table - Silica by XRD.................................51
Table 8-8. Measurement Perfonnance Criteria Table - Asbestos by TEM/SEM(1)............... 52
Table 8-9. Measurement Performance Criteria Table - PMIO and PM2.5 by Gravimetry..... 53
Table 10-1. RCRA Waste Characterization Analytical Method, Container, Preservation and
Holding Times for selected aqueous and non-aqueous matrices.
Table 11-1. Summary of Preparation and Analytical Methods........................................ 75
Table 12-1. Summary of Media, Preservation, and Holding Time Requirements......... 80
Table 13-la. Maintenance, Testing, and Inspection Activities Associated with Metals
(TSP filters) Collected with High Volume Samplers 87
Table 13-lb. Maintenance, Testing, and Inspection Requirements for the Ohio Lumex
RA915+ Mercury Analyzer 88
Table 13-lc. Maintenance, Testing, and Inspection Requirements for the PS-1 Sampler
Used for PCDDs/PCDFs and PAHs 90
Table 13-Id. Maintenance, Testing, and Inspection Requirement for the Anderson
RAAS Sampler Used for PMIO and PM2.5............................................................... 91
Table 13-2. Instrument Maintenance, Testing and Inspection Requirements for Fixed
Laboratory Analyses............................................................................ 92
Table 13-3a. Calibration Requirements for High Volume Samplers. .94
Table 13-3b. Calibration Requirements for the Ohio Lumex RA915+ Mercury Analyzer ..95
Table 13-3c. Calibration Requirements for PS-1 Samplers................................................. .. 96
Table 13-4. Summary of Calibration Procedures for Fixed Laboratory Analyses.............. 98
Figures
Figure 4-1. Organization Chart and Communication Pathway................ 13
Figure 6-1. Project Timeline........................................................................ 26
Figure 7-1. Site Location Map and Ground Level Monitoring Locations 31
Figure 7-2. Roof-Top and Scaffolding Monitoring Locations................. 32
Figure 12-1. Sample Label......................................................................... .. 84
6
CITY_DEP_WORBY_CANNATA_SUBP_000070940
NYC-WTC_000423890
OCR can misread numbers and units. Confirm readings against the page image before using them.