NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 110 pages

QA Plan for Air Monitoring Program, Sept 2005

Machine-extracted title · confidence 55%

Quality Assurance Project Plan for environmental air monitoring and waste management at Greenwich and Thames sites; Sept 30, 2005.

NYC-WTC_000423885–000423994
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

8.2.3 Representativeness

Representativeness is a qualitative parameter which expresses the degree to which the data and sampling design accurately and precisely represent a characteristic of a population, parameter variations at a sampling point, a process condition, or an environmental condition within a defined spatial and/or temporal boundary.

Representativeness is a qualitative parameter that is dependent upon the proper design of the sampling program and the laboratory quality control program. The air monitoring network has been designed so as to capture air emissions if any at potential release points during building deconstruction. In addition monitoring data from the neighboring LMDC 130 Liberty Street deconstruction project twelve (12) station monitoring network will be reviewed and compared with data generated for the Greenwich Street deconstruction project when necesary to examine the source(s) of any exceedances that may occur during the term of the project. These analyses include contributions from regional or background air quality, effects of the deconstruction activities as well as contributions attributable to activities on site or off site upwind or downwind of the 133-135 Greenwich Street and 21-23 Thames Street property itself.

Measures to Ensure Representativeness of Field Data Representativeness is dependent upon the proper design of the sampling program and will be satisfied by ensuring that the Ambient Air Monitoring Program, referenced sampling methodologies, and required QC procedures are followed and that proper sampling, sample handling, and sample preservation techniques are used. Refer to Section 10.1 of the QAPP for the sampling design which will provide representative data over the site. Representativeness may also be assessed by the use of field duplicate samples. By definition, field duplicate samples are collected so they are equally representative of a given point in space and time. In this way, they provide both precision and representativeness information. As stated previously, field duplicate samples will generally be collected at a frequency of one per week per analytical parameter. In general, representativeness in the field will be maximized by following the reference sampling methodologies, proper sample preservation procedures, utilizing experienced/trained sampling crews, and conducting field audits.

Measures to Ensure Representativeness of Laboratory Data Representativeness in the laboratory is ensured by using the proper analytical procedures, appropriate methods, and meeting sample holding times. Following the detailed requirements outlined in the EPA and NIOSH methods will maximize the representativeness of the laboratory data.

8.2.4 Comparability

Comparability is a qualitative parameter that expresses the confidence with which one data set can be compared to another.

42

CITY_DEP_WORBY_CANNATA_SUBP_000070976

NYC-WTC_000423926

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423926Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →