Ambient Air Monitoring Program, Deconstruction, 2005

Machine-extracted title · confidence 42%

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

NYC-WTC_000423219–000423350
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■< Z ■<

o o io Ambient Air Monitoring Program Quality Assurance Project Plan 130 Liberty Street - NY, NY Section No. 8 Revision No.: 0 Date: September 7, 2005 co

I Lower Manhattan Development Corporation Page 47 of 124 ■D c o o CT o o' to ■D o o to 3. CD 03 CD Table 8-3. Measurement Performance Criteria Table - PAHs by GC/MS-SIM o QC Sample or Activity DQI o Frequency Measurement Performance Criteria Corrective Action o c Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, and/or Precision-Overall 3 samples are > 5x QL qualify data. CD *No situation where one result is detected at > 5x QL and other result is not detected Internal Standards Every sample, Percent recoveries 25-150% Reanalyze and/or qualify data. Accuracy/Bias (extraction spike) blank, QC Method Blanks 1/batch No target compounds > QL Reclean, reanalyze and/or qualify Accuracy/Bias- data. Conlaminatioir Field/Trip Blanks 1/day No target compounds > QL Reclean, reanalyze, and/or qualify Accuracy/Bias - data. Contamination Laboratory Control Sample 1/batch Percent recoveries 60-140% Determine cause of problem, Accuracy/Bias reanalyze, and/or qualify data. Laboratory Control Sample 1/batch Percent recoveries 60-140%; RPDs < 50 Determine cause of problem, Accuracy/Bias and Duplicate reanalyze, and/or qualify data. Precision Recovery Standards Every sample, -50% to -1-100% of area counts in Reanalyze and/or qualify data. Accuracy/Bias (pre-analysis splice) blank, QC continuing calibration standard; + 20 seconds of retention times in continuing O calibration standard Field Spike Every Sample Percent recoveries 60-120% Reanalyze and/or qualify data. Accuracy-Overall (prior to sampling)- 13C- O fluorene at 1000 ng m Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness PUF/XAD Media Cleaning 1/batch cleaned No target compounds > QL Reclean and retest media. Accuracy/Bias- o Verification Check Contaminatioir J] □0 PFTBA Tune Every day, prior Masses within 0.45 amu of target mass for Retune instrument, reanalyze PFK. Accuracy/Bias to sample masses 69, 219, and 264 analysis

s > Field duplicates may not be consistently collected at a frequency of 1/week during Phases 1 and II as tire location selected for analysis will be dictated by PMic measurements. Will be collected at a frequency of 1/day; during Phase I and II only 1 field/trip blank per week will be analyzed. Reanalyze: refers to reanalysis of same exhact.

c □0 o o o o tn 00 rv) co tn

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423266Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →