NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 132 pages

Ambient Air Monitoring Program, Deconstruction, 2005

Machine-extracted title · confidence 42%

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

NYC-WTC_000423219–000423350
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 16 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 122 of 124

16.2.5 Completeness

Completeness is the ratio of the number of valid sample results to the total number of samples analyzed or processed. Following completion of the testing, the percent completeness will be calculated by the following equation:

, (number of valid measurements') Completeness =------------------------------------------ % lUU (^number of measurements planned)

Overall completeness will be reviewed for each analytical parameter. The data usability assessment will include any limitations on the use of the data, if limited to a particular data set, parameter, or laboratory. If the results of the evaluation of completeness yield data which are not usable, the Data Validation memoranda will identify how this problem will be resolved.

16.2.6 Data Limitations and Actions

The field and laboratory data collected during this investigation will be used to achieve the objectives identified in Section 8.0 of this QAPP. The QC results associated with each analytical parameter will be compared to the objectives presented in this QAPP. Data generated in association with QC results meeting the stated acceptance criteria (i.e., data determined to be valid) will be considered usable for decision-making purposes. Limitations on the use of the data will be stated and explained, if necessary.

In addition, the data obtained may be both qualitatively and quantitatively assessed on a project­ wide, location specific, and parameter-specific basis. Results of the measurement error assessments may be applied against the site as a whole; any conclusions will be documented in data validation or QA reports. Data generated in association with QC results not meeting the stated acceptance criteria may still be considered usable for decision-making purposes, depending on certain factors. This assessment will be performed by the TRC Project Manager, in conjunction with the TRC Project QA Officer. In general, qualified data will still be usable for project objectives. Qualified data exhibiting concentrations close to the project Action Levels will be evaluated further to determine if there is a potential bias caused by the QC nonconformance which may have caused a false exceedance or a false non-exceedance. Factors to be considered in this assessment of field and laboratory data will include, but not necessaiily be limited to, the following.

• Conformance to the field methodologies proposed in the QAPP, • Conformance to the EPA and NIOSH methods provided in the QAPP, • Adherence to proposed sampling sttategy, • Presence of elevated detection limits due to matrix interferences present in background ambient air or contaminants present at high concentrations, • Presence of analytes not expected to be present.

CITY_DEP_WORBY_CANNATA_SUBP_000058310

NYC-WTC_000423341

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423341Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →