NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 132 pages

Ambient Air Monitoring Program, Deconstruction, 2005

Machine-extracted title · confidence 42%

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

NYC-WTC_000423219–000423350
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 16 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 120 of 124

All data from the Background Phase will be subjected to a limited validation, which includes, at a minimum, a completeness check, an evaluation of chain-of-custody and sample login documents, an overall evaluation of data and potential usability issues, technical holding times, and QC sample results (blanks, surrogate spikes, MS/MSDs, calibrations, matrix duplicates, and LCS, etc.). Pollowing this, a limited validation will be performed on a subset of the data. Por the first two months of the program, the validation will be performed on a weekly basis followed by a monthly basis thereafter. Completeness checks will be administered on all data to determine whether deliverables specified in the QAPP are present. The reviewer will determine whether all required items are present and will request copies of missing deliverables. Pield notes will be reviewed in conjunction with the laboratory data to allow for an overall assessment.

Upon completion of the validation, a report will be prepared summarizing the elements reviewed. Validated data will be used to generate tables. Potential validation qualifiers are as follows:

U - Not detected at the specified quantitation/detection limit UJ - Estimated nondetect J - Estimated value R - Unusable data point N - Presumptively present

16.2 Data Usability

The purpose of this section is to indicate the methods by which it will be ensured that the validated laboratory data collected for this investigation are consistent with the project quality objectives established for the project, to ensure the quality of data was sufficient for its intended use, and to identify trends, relationships, and anomalies in the data. Conclusions based on the data, limitations on the use of the data, and the determination if data gaps exist will be included in the Data Validation memoranda. This will be performed on a per sample batch basis.

16.2.1 Precision

The RPD between the LCS and LCS duplicate or sample and sample duplicate, is calculated to compare to precision objectives. LCS/LCS duplicates and laboratory duplicates will be used to assess analytical precision and the field duplicates will be used to assess project precision. The RPD will be calculated according to the following formula:

(Amount in Sample 1 - Amount in Sample 2) KrU =------------------------------------------------------------X 11) (J 0.5 (Amount in Sample 1 + Amount in Sample 2)

The impact of analytical imprecision, project imprecision, and overall imprecision (when both analytical and project precision tests show problems) on data usability will be assessed. If the

CITY_DEP_WORBY_CANNATA_SUBP_000058308

NYC-WTC_000423339

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423339Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →