Filter (HEPA) hood. Samples handled outside of the HEPA hood will be covered with aluminum foil or placed in sealed glass jars.

7.0 Apparatus and Materials

1. HEPA negative flow hood 2. Forceps 3. Kimwipes 4. Stainless steel spatula 5. Weighing paper 6. Programmable furnace [not required for validation study] 7. Ceramic crucibles with lids [not required for validation study] 8. Analytical balance (accuracy to 0.0005 g) 9. Retsch ultrasonic sieve shaker (AS200 Basic), or similar [not required for validation study] 10. Sample sieves, 3-inch diameter (recommended), 150-pm (100-mesh) opening, with lid and bottom pan similar [not required for validation study] 11. SEM aluminum sample stubs 12. Conductive carbon adhesive tabs 13. Eppendorf pipette, lO-pE capacity 14. Disposable pipette tips 15. 1 - 10 mL pipette 16. Glass vials for sonicating dust in isopropanol suspension (holds 10-mL volume) 17. Razor blade 18. Ultrasonic bath 19. 50 mL glass beaker 20. Polycarbonate filters (25-mm diameter, 0.4-nm pore size) 21. Polycarbonate filters (13-mm diameter, 0.4-pm pore size), or borer to cut larger filters to SEM stub size 22. 11-mm diameter cork borer 23. Millipore filter apparatus for use with 25 mm filters 24. 125 mL Nalgene bottles 25. Hand-held vacuum pump 26. High-vacuum carbon evaporator with rotating stage 27. Glass petri dishes with lids 28. Adobe Photoshop Software, or similar 29. Glass petrographic slides 30. Glass cover slips 31. Polarized light microscope for mineral identifications 32. Scanning Electron Microscope with the following attributes: a. Resolution: 5 nm (at 25 kV, WD=10 mm - system dependent) or better b. Accelerating Voltage: 10 to 20 kV c. Minimum magnification range: 50x to 200,000x d. SEI (secondary electron image) e. BEI (backscattered electron image) f. Energy dispersive x-ray detector and analyzer for EDS analysis

38

CITY_DEP_WORBY_CANNATA_SUBP_000057576

NYC-WTC_000423049

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423049Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →