NYC 9/11 Public Portal Document
Cusfomerhocused SolufIons
1430 Broadway, 10th Fl. New York, New York 10018
Phone: (212) 221-7822 - Fax: (212) 221-7840
LMDC Air Metals Profile
Client Lower Manhattan Development Corporation Job Number 46600-0000-00001
Address One Liberty Plaza, 20th Floor Date Received 2/10/2005
New York, NY 10006 Date Analyzed 2/10/2005
Collected By K. DaRocha Job Location 130 Liberty Street
Collected 2/9/2005
Potometer Standard
Lab ID 010500473-0001 Matrix Air
Field ID M-020905-097
Location Washington Street/Albany Street
Parameter Start End Flow Volume Result Units MDL MCL Flag
Barium, Total 16:03 16:02 3.9 5612.1 <0.8909 Hg/m3 0.8909 500
Beryllium, Total 16:03 16:02 3.9 5612.1 <0.0356 Hg/m3 0.0356 1
Cadmium, Total 16:03 16:02 3.9 5612.1 <0.0356 Hg/m3 0.0356 2.5
Chromium, Total 16:03 16:02 3.9 5612.1 <0.0891 Hg/m3 0.0891 500
Copper, Total 16:03 16:02 3.9 5612.1 <0.1782 Hg/m3 0.1782 500
Lead,Total 16:03 16:02 3.9 5612.1 <0.0891 Hg/m3 0.0891 30
Manganese, Total 16:03 16:02 3.9 5612.1 <0.1336 |jg/m3 0.1336 1000
Nickel, Total 16:03 16:02 3.9 5612.1 <0.1782 Hg/m3 0.1782 500
Zinc, Total 16:03 16:02 3.9 5612.1 <0.1782 Hg/m3 0.1782 2500
Lab ID 010500473-0002 Matrix Air
Field ID M-020905-098
Location Albany Street/Greenwich Street
Parameter Start End Flow Volume Result Units MDL MCL Flag
Barium, Total 16:06 16:05 4 5756 <0.8687 Hg/m3 0.8687 500
Beryllium, Total 16:06 16:05 4 5756 <0.0348 Hg/m3 0.0348 1
Cadmium, Total 16:06 16:05 4 5756 <0.0348 Hg/m3 0.0348 2.5
Chromium, Total 16:06 16:05 4 5756 <0.0869 Hg/m3 0.0869 500
Copper, Total 16:06 16:05 4 5756 <0.1737 Hg/m3 0.1737 500
Lead,Total 16:06 16:05 4 5756 <0.0869 Hg/m3 0.0869 30
Manganese, Total 16:06 16:05 4 5756 <0.1303 Hg/m3 0.1303 1000
Nickel, Total 16:06 16:05 4 5756 <0.1737 Hg/m3 0.1737 500
Zinc, Total 16:06 16:05 4 5756 <0.1737 Hg/m3 0.1737 2500
MDL = Minimum Detection Limit
MCL = Maximum Contaminant Level
> MCL = Exceeds Maximum Contaminant Level
Samples analyzed by EMSL Analytical, Inc.; NY ELAP ID# 10872 and 11506 Page 1 of 3