Table 4 Exterior Netting - Dioxin Microvacuum Sample Results Dioxin/ Wipe (Method 8290)

LMDC 130 Liberty Street New York. New York April 22, 2005

WHOTEQ Sample ID Lab Sample ID Sample Date Sample Type Floor Location (ND=1/2;

1-Dioxin-020605 G220-32-1C 2/10/2005 Wipe 1 1ST FL EXT BLDG. MESH/NET AROUND EXT 1.47 2-Dioxin-020605 G220-32-2C 2/10/2005 Wipe 1 1ST FL EXT BLDG. MESH/NET AROUND EXT 2.39 3-Dioxin-020605 G220-32-3C 2/10/2005 Wipe B BSMT "B" EXT BLDG. MESH/NET AROUND EXT 0.83 4-Dioxin-020605 G220-32-4C 2/10/2005 Wipe A BSMT "A" EXT BLDG. MESH/NET AROUND EXT 1.59 5-Dioxin-020605 G220-32-5E 2/10/2005 Wipe 1 1ST FL EXT BLDG. MESH/NET AROUND EXT 1.15 1-Dix-FL40-033005 G220-38-1B 3/30/2005 Wipe 40 West side between columns 6 and 7 0.55 2-Dix-FL26-033005 G220-38-2B 3/30/2005 Wipe 36 West side between columns 6 and 7 0.56 3-Dix-FL32-033005 G220-38-3B 3/30/2005 Wipe 32 West side between columns 6 and 7 0.58 4-Dix-FL16-033005 G220-38-4B 3/30/2005 Wipe 16 West side between columns 6 and 7 2.56 4A-Dix-FL16-033005 G220-38-5B 3/30/2005 Wipe 16 West side between columns 6 and 7 0.21 5-Dix-FL8-033005 G220-38-6B 3/30/2005 Wipe 8 West side between columns 6 and 7 1.49

O na/m2 1^ Arithmetic Mean (ND=1/2) 1.32 o May 2003 Benchmark^ 2 m April 2003 Background Assessment^ 0.693 September 2002 WTC Indoor Assessment^ o Tier I >120 J] □0 Tier II 120 to 4 (or background) 'o Tier III <4 (or background) > z References:

s c □0 2

3 World Trade Center Indoor Environment Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contamina Potential Concern (COPC) Committee. United States Environmental Protection Agency, May 2003. World Trade Center Background Study Report, Interim Final. United States Environmental Protection Agency, Region 2, April 2003. 1"° World Trade Center Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks. Contaminants of Po o Concern (COPC) Committee of the World Trade Center Indoor Air Taskforce Working Group. Peer Review Draft, September 2002. o o o tn r\o TRC Environmental Corporation 00 co 05

NYC-WTC_000422145

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000422145Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →