130 Liberty Street -Building Netting April 25, 2005 Supplemental Investigation Summary Page 10

Zone 5). These results are consistent with the highly variable nature of WTC dust. Results of this study were higher than the concentrations found in this investigation by at least one order of magnitude.

3.5 Polycyclic Aromatic Hydrocarbons (PAHs)

Ten wipe and one duplicate sample was collected from street level and at higher elevations designated by the Building floor as detailed in Section 3.1. The carcinogenic PAHs results were used to calculate the benzo(a)pyrene (BaP) equivalent to measure the relative potency. The BaP equivalent is computed by multiplying the concentration of each compound by the TEF. The products of the individual concentrations and the TEFs ai-e then added to obtain the BaP equivalent for that sample. For this investigation, one- half of the detection limit was used for compounds that were not detected. BaP equivalent results ranged from 21.77 micrograms per square meter (ug/m^) to 74.48 ug/m^ with an arithmetic average of 33.29 ug/nr. All ten sample results were below the Tier III Indoor Assessment value of 300 ug/nV. Sample results are provided in the attached Table 5.

A limited data validation was performed the samples in accordance with the USEPA Contract Laboratory Program National Functional Guidelines for Organic Data Review EPA 540/R-99/008 (October 1999). In general, the data appear to be valid as reported and may be used for decision-making purposes. Potential low bias exists for all samples due to an elevated cooler temperature and, for the samples collected in February, a slight holding time exceedance. As a result, positive and non-detect results for all PAHs in all samples were qualified as estimated (J/UJ).

According to the Initial Building Characterization Report, there was significant variation in the PAH testing results collected from the Building dust samples. The samples containing PAH ranged from a low concentration of 3 ug/nV (from Zone 1) to a maximum concentration of 11,555 ug/m“ (in Zone 2). These results are generally greater than the results of this investigation.

3.6 Man Made Vitreous Fibers (MMVF)

Ten MMVF wipe and one duplicate sample were collected from street level and at higher c elevations designated by the Building floor as detailed in Section 3.1. The sample results CD E ranged from less than 0.014 str/cnV to 162.04 str/cnr with an arithmetic average of 42.9 3 o str/cm^. Results and the average were at least three orders of magnitude less than the Tier o Q TO co ■c co o CM Q_ CM o O Z O 3 O 0. o' O) O 6 z CITY_DEP_WORBY_CANNATA_SUBP_000052827 z

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000422136Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →