Rooftop bulk/air sampling summary, 2002

Machine-extracted title · confidence 42%

Detailed chain-of-custody table for bulk and air samples with positive asbestos readings.

NYC-WTC_000421430–000421506
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document -ra;a a-: t Jiai: ± J. i: r-lii r JSK'X: e. - r •.

02/20/2002 09:24 FAX @05?

illHii 'T Wi;,.

ENVIRONMENTAL CONSULTANTS, INC Deewnber 11,2001 Revised from September 27, 2001

Ms, Beth Trioio Ma^ai Group LLC (100 John Street) One West Street New York, NY 10004

Re: Ambient Air Monrtorinq at 100 John Sheet, New York NY

Dear Ms. Triolo:

JLC Environmental Consultants, !nc (JLC) conducted ambient air sampling for asbestos at various locations at foe above site on September 19, 2001 The asbestos air samples were analyzed using foe Phase Contrast Microscopy (PGM) Methodology

The analytical results of foe air samples indicated that sample numbers 021, 031, 036, 037, 038, 039 were above the acceptance criteria of at or below 0.01 fibers per cubic centimetere.

The air samples (nos, 021, 031, 036, 037, 038, 039} that failed to meet the acceptance criteria of at or below 0.01 fibers per cubic centimeters using the Phase Contrast Microscopy Method were then submitted for analysis using the Transmission Electron Microscopy (TEM) Methodology NIOSH 7402 Method. This method is the most stringent for performing analysis to determine asbestos content.

rhe TEM/analytical resuhs of foe air samples indicated that sample numbers 021, 031, 036. 037. 038/039 were below foe acceptance criteria of at or below 0.01 fibers per cubic centimeters and that no asbestos fibers greater than foe limit listed previously was identified in these samples.

Based on these results the sampled locations are considered safe for occupancy.

The air sampling and analysis were done utilizing applicable Federal, New York State and New York City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58), EPA (NESHAPS 40 CFR Part 61), and TSCA Title 1! AHERA/ASHARA (40 CFR Part 763) Asbestos Regulations; the New York State Department of Labor industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

200 Park Ava Soufh, Suite 1001 New York, New York 10003 » Tel: (212) 420-8119 * Fax: (212] 420-6092 10966

CITY_DEP_WORBY_CANNATA_SUBP_000027741

NYC-WTC_000421487

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000421487Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →