NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

Environmental Community Air Monitoring Plan, Greenwich Street

Machine-extracted title · confidence 52%

Plan for Community Air Monitoring at The Greenwich Street properties and related sites.

NYC-WTC_000420647–000420775
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assmance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Method (200 filter and extraction; TO-9A L/min for PUF cartridge 45 days 24 hours from extraction to analysis PCBs SW-846 7.2 m^ PUF cartridge Cool to 4“ C; 14 days to Method (5L/min keep in dark extraction; 8082 for 24 40 days hours) from extraction to analysis PAHs SW-846 288 m’ Quartz fiber Cool to 4“ C; 14 days to Method (200L/min filter, keep in dark extraction; 8270C for 24 PUF/XAD-2 40 days hours) sandwich from cartridge extraction to analysis

Table 12-2. Waste Samling - Aqueous and (Solid) Summary of Media, Preservation, and Holding Time Requirements Analytical Analytical Estimated Media Preservatio Maximum Parameter Method Sample n Holding Volume Requireme Time nts ignitability ASTM method p- 16oz None - no holding D-93-79 or D-93- jars and 1 time 80 or D-3278-78 -8 oz jar for solid samples) reactive SW9012 A, 7.3 p- 16oz None 14 day holding cyanide jars and 1 time -8 oz jar for solid samples) reactive SW 9030 B/ 9034 (2 - 16 oz None 7 day holding sulfide jars and 1 time -8 ozjar for solid samples) corrosivity SW846 Method (2 - 16 oz None to be analyzed 9045D or 9040C jars and 1 as soon as possible -8 oz jar for solid samples)

82

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010963

NYC-WTC_000420728

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420728Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000420513

Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.

Similar indexed content

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

Compare copies and versions →