Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Method (200 filter and extraction; TO-9A L/min for PUF cartridge 45 days 24 hours from extraction to analysis PCBs SW-846 7.2 m’ PUF cartridge Cool to 4° C; 14 days to Method (5L/min keep in dark extraction; 8082 for 24 40 days hours) from extraction to analysis PAHs SW-846 288 m’ Quartz fiber Cool to 4° C; 14 days to Method (200L/min filter, keep in dark extraction; 8270C for 24 PUF/XAD-2 40 days hours) sandwich from cartridge extraction to analysis

Table 12-2. Waste Samling - Aqueous and (Solid) Summary of Media, Preservation, and Holding Time Requirements Analytical Analytical Estimated Media Preservatio Maximum Parameter Method Sample n Holding Volume Requireme Time nts ignitability ASTM method (2 - 16 oz None - no holding D-93-79 or D-93- jars and 1 time 80 or D-3278-78 -8 ozjar for solid samples) reactive SW 9012 A, 7.3 p - 16 oz None 14 day holding cyanide jars and 1 time -8 ozjar for solid samples) reactive SW 9030 B/ 9034 p - 16 oz None 7 day holding sulfide jars and 1 time -8 ozjar for solid samples) corrosivity SW846 Method (2 - 16 oz None to be analyzed 9045D or 9040C jars and 1 as soon as possible -8 ozjar for solid samples)

82

CITY_21MC100_003240728

NYC-WTC_000445026

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000445026Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

NYC-WTC_000440780

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →