NYC-WTC_000451808
Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.
91 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Plan for Community Air Monitoring at The Greenwich Street properties and related sites.
NYC-WTC_000420647–000420775OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assuiance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005
• High Flow Rotometer - 2.0 to 20.0 1pm
10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)
PAH samples will be collected using high-volume air samplers fitted with non-size selective quartz fiber filters and sorbent cartridges. This approach, as described in EPA Method TO-13 A, does not collect particulate matter representative solely of potential inhalation exposure, but provides for a total of respirable and non-respirable PAHs. Sorbent traps containing polyurethane foam (PUF) and XAD-2® resin in a “sandwich” configuration. The General Metals Works (GMW) PS-1 high volume sorbent sampler (or performance equivalent) located at each monitoring station will be operated at a flow rate of 200 to 300 liters per minute with a sampling period of approximately 24 hours for a resulting total air volume of approximately 288 ms - 432 ms. The filters and sorbent cartridges will be solvent pre-cleaned and vacuum dried by the analytical laboratory. The pre-cleaned filters and cartridges will be stored wrapped in aluminum foil (or otherwise protected from light) in a Ziploc bag, and over wrapped with bubble wrap until they are carefully installed on the sampler on site. At the conclusion of each sampling period, the sample is recovered from the sampling train by placing the filter inside the glass cartridge. The cartridge is then wrapped with aluminum foil and it is placed back into its original shipping container, labeled, and transported to the analytical laboratory for processing. The amount of air sampled through the filters and cartridges will be recorded and the filter/cartridge set placed in an appropriately labeled container and shipped to the laboratory for analysis. Equipment and supplies utilized with this sampling approach arc as follows:
• High-Volume Sampler - General Metals Works model PS-1 (or performance equivalent). Capable of pulling ambient air through the filter/sorbent cartridge at a flow rate of approximately 200-300 1pm over a 24-hour sampling period. • Sampling Module - Metal filter holder capable of holding a 102-mm circular particle filter supported by a 16-mesh stainless-steel screen and attaching to a metal cylinder capable of holding a 65-mm O.D. (60-mm ED.) x 125-mm borosilicate glass sorbent cartridge containing PUF and XAD-2® resin in the “sandwich” configuration. To ensure air-tight seals, the filter holder is equipped with inert sealing gaskets placed on either side of the filter and inert pliable gaskets placed at either end of the glass sorbent cartridge. • High-Volume Sampler Calibrator - Capable of providing multi-point resistance for the high volume sampler. • Quartz Fiber Filter - 102 mm binderless quartz microfiber filter. (Provided by the laboratory, pre-cleaned and weighed.) • Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the cartridge. • XAD-2® Resin - Used to assemble the PUF/XAD-2 “sandwich” cartridges. Supelco (or equivalent). Pre-cleaned and assembled by the analytical laboratory. • White Cotton Gloves - For handling the filters and cartridges.
60
CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010941
NYC-WTC_000420706
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000451808
Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.
91 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420513
Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.
91 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427716
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
91 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424323
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
91 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423504
Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.
91 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426348
Plan document outlining community air monitoring for Greenwich and Thames sites.
91 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442410
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites.
92 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444945
Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.
90 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427582
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
89 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447434
Chain of custody plan for Greenwich Street/Thames Street site air monitoring.
90 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000440780
Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.
90 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424189
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
89 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000444945
Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451808
Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447434
Chain of custody plan for Greenwich Street/Thames Street site air monitoring.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443742
Chain-of-custody form for Environmental Community Air Monitoring Program plans at Greenwich Street and Thames Street, dated November 4, 2005.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000440780
Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424323
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.
Similar indexed content
Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.
Similar indexed content
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
Similar indexed content
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
Similar indexed content
Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.
Similar indexed content