Part V - Quality Assurance Project Plan 133-135 Greenwich Strcct/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

13.3.2 Analytical Laboratory Supplies/Consumables Critical supplies and sample containers will be inspected in the following manner. Critical Supplies and Inspection Requirements Responsible Individual Consumables and Acceptance Criteria Sample bottles, media Visually inspected upon Sample Custodian receipt for cracks, breakage, cleanliness. Must be accompanied by certificate of analysis.______________ Chemicals and reagents Visually inspected for Laboratory Analysts proper labeling, expiration dates, appropriate grade. Record lot numbers of reagents used for calibration.

Supplies and consumables not meeting acceptance criteria will initiate the appropriate corrective action. Corrective measures may include notification of vendor and subsequent replacement of defective or inappropriate materials. All actions will be documented in the project files.

Table 13-.4. Summary of Calibration Procedures for Fixed Laboratory Analyses Parameter Frequency of Acceptance Criteria Corrective Instrument Calibration Action Metals/ICP/MS Initial Calibration: NA; monitored by IVC Perform daily, every 24 necessary hours or every time equipment instrument us set maintenance up______________ and check Initial Calibration 90-110% of true value calibration Verification: standards. immediately after initial calibration Continuing 90-110% of true value Calibration Verification: after every 10 samples and at end of analytical sequence.

98

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010845

NYC-WTC_000420610

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420610Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →