NYC-WTC_000442410
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites.
93 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.
NYC-WTC_000420513–000420646OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan 133-135 Greenwich Strcct/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005
I PM 25 I Annual calibration of balance by outside certification. (^) The maintenance responsibilities for fixed laboratory instruments will be assigned to the Laboratory Section Managers. Laboratory analysts will be responsible for daily checks and calibrations and for reporting any problems with the instruments. The maintenance schedule will follow the manufacturer’s recommendations. Laboratory personnel will also be responsible for ensuring that critical parts are kept with the fixed laboratory instruments. Critical spare parts will be immediately available to reduce potential downtime. The inventory will primarily contain parts that are subject to frequent failure, have limited useful lifetimes, and/or cannot be obtained in a timely manner. Annual preventative maintenance service visits will involve cleaning, adjusting, inspecting, and testing procedures designed to minimize product failure and/or extend the product’s life. Between visits, laboratory analysts will be responsible for performing routine operator maintenance and cleaning in accordance with the manufacturer’s specifications.
13.2 Instrument/Equipment Calibration and Frequency
13.2.1 Field Equipment
All materials, including standards or standard solutions, will be dated upon receipt, and will be identified by material name, lot number, purity or concentration, supplier, recipient’s name, and expiration date. All materials must be National Institute of Standard and Technology (NIST)- traceable reference materials.
Metals (Low-Volume Area Sampler) Table 13-3a summarizes the calibration procedures associated with the low volume samplers used to collect metals (MCE) samples.______________________________________________________________ Table 13-3a. Calibration Requirements for Low Volume Area Samplers Equipment Activity Acceptance Corrective Action Criteria Low Volume Area Rotometer calibration at Within Method Replace Sampler Sampler every sample run (NIOSH 7300) initiation and accepted range 1- termination. Periodic 4 1pm check during nin. Calibration records maintained and tracked by Quality Assurance Officer and Field Sampling Coordinator.
94
CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010841
NYC-WTC_000420606
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000442410
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites.
93 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451808
Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.
90 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427582
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
88 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424189
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
88 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423370
Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.
88 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426214
Plan document outlining community air monitoring for Greenwich and Thames sites.
88 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426688
Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.
89 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425068
Title and approval sheet for Environmental Community Air Monitoring Program and plan at Greenwich and Thames sites.
89 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426957
Plan for environmental community air monitoring at 133-135 Greenwich & 21-23 Thames, Sept 2005.
89 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424476
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
89 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427415
CoC document detailing plan for Environmental Community Air Monitoring at Greenwich Street sites.
89 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427716
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
91 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000424189
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423370
Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427582
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426214
Plan document outlining community air monitoring for Greenwich and Thames sites.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426688
Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442410
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000442410
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites.
Similar indexed content
Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.
Similar indexed content
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
Similar indexed content
Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.
Similar indexed content
Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.
Similar indexed content