Part V - Quality Assurance Project Plan 133-135 Greenwich Strcct/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Table 12-1, Summary of Media, Preservation, and Holding Time Requirements Analytical Analytical Estimated Media Preservation Maximum Parameter Method Sample Requirements Holding Volume Time Metals SW-846 1440 m3 8” X 10” None 180 days Method (1000 quartz fiber to analysis 6020A L/min for filter 24 hours) Total Mercury EPA 0.576 m3 2 small None 28 days to method (0.4 L/min ioadated analysis 324, for 24 carbon traps modified hours) in series Asbestos AHERA 2.88 m3 (6 25mm None None (TEM) L/min for diameter minimum cassette with of 8 hours) 0.45 pm pore size, mixed cellulose ester filter Asbestos German 2.88 m’ (6 25mm None None (SEM) VDI L/min for diameter Method minimum cassette with 3492 of 8 hours) 0.1 pm pore size, polycarbonat e filter Silica- NOSH 1.0 m3 (2.0- SKC None None Respirable Method 2 1 L/min aluminum 7500 for 8 cyclone; 37 hours) mm diameter cassette with 5.0 pm pore size, polyvinyl chloride filter Particulate PM 40 CFR 24.05 m3 Micro-Quartz None None 10 Pai-t 50, (16.7 Appendix L/min for J 24 hours Particulate PM 40 CFR 24.05 m3 47 mm None 25 Part 50, (16.7 Teflon filters Appendix L/min for L 24 hours

83

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010830

NYC-WTC_000420595

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420595Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →