NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 134 pages

Environmental Community Air Monitoring Program plan, Greenwich/Thames

Machine-extracted title · confidence 52%

Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.

NYC-WTC_000420513–000420646
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Strcct/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

media, and returned to the laboratory for analysis.

Total Mercury In addition, during the background phase of the program, the accuracy and precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the accuracy and precision of the method under actual field sampling condition. Following the background phase, one field spike will be performed every other week.

10.3.5 Breakthrough Checks

Separate analyses of both front and back half portions of carbon traps for mercury will be performed during the background phase to allow for an assessment of analyte breakthrough. The breakthrough assessment will be perfoimed on all stations during the background phase. Breakthrough on the back half of the trap must be < 2% of the front half of the trap or < 5 ng per trap. If breakthrough criteria are consistently met during the background phase, subsequent measurement will be performed with the front and back halves of the carbon traps combined for analyses.

10.3.6 Media Certification Checks

Media for all analyses collected a on time-integrated basis will be certified clean from the laboratories. The certifications will be performed as batch checks and results will be stored in the project files.

11.0 ANALYTICAL REQUIREMENTS

11.1 Analytical Methods

This section of the QAPP describes the analytical techniques that will be used by the fixed laboratories to generate definitive data for the project. It documents the fixed laboratory analytical methods that will be used to meet measurement performance criteria and achieve the project-required quantitation limits for all contaminants of concern in the specific matrices as identified on Tables 8-la-c.

11.1.1 Fixed Laboratory Analytical Methods and SOPs

Table 11-1 details the analytical methods that will be used in this investigation

11.1.2 Fixed Laboratory Analytical Method/SOP Modifications

The cited methods will be followed as written with the exceptions summarized below. These modifications do not adversely affect the quality or usability of the data as sufficient quality control analyses will be performed demonstrating adequate method performance with these modifications.

70

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010817

NYC-WTC_000420582

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420582Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →