Part V - Quality Assurance Project Plan 133-135 Greenwich Strcct/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

rab/e 8-2. Measurement Performance Criter/'a Tab/e-Meta/s ICP/MS QC Sample or Frequency Measurement Corrective DQI Activity Performance Action Criteria Field 1/Week *RPD < 40 Assess Precision- Duplicates when positive laboratory Overall results for both precision; and samples are > /or qualify data. 5x QL *No situation where one result is detected at > 5x QL and other result is not detected Laboratory 1/ prep batch RPD < 20 if Qualify data Precision- Duplicates results are > Laboratory 5x QL Laboratory 1/prep batch Percent Determine Accuracy/Bias Control Sample recoveries 75- cause of 125% problem reanalyze and/or qualify data. Laboratory 1/prep batch Percent Determine Accuracy/Bias Control Sample recoveries 75- cause of and Precision 125% RPD < problem 20 reanalyze and/or qualify data. Serial Dilution 1/batch ±10% of Qualify data. Accuracy/Bias original result Interference 1/8 hours Percent Recalibrate and Accuracy/Bias Check Sample recoveries 80- reanalyze 120% and/or qualify data. Calibration 1/10 samples Absolute value Reclean, Accuracy/Bias- Sample of target metal reanalyze, Contamination must be < QL and/or qualify data.

40

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010787

NYC-WTC_000420552

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420552Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →