NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

ATC project report, I.S. 89M, Jan 16 2002

Machine-extracted title · confidence 41%

ATC report covering project and air monitoring services at I.S. 89M, Warren Street.

NYC-WTC_000420356–000420357
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

01/28/2002 16:48 FAX 212 353 8306 ATC 0033

104 East 25th St N&w York, New York 10010 www.atc-enviro.com , 212.353.8230 I Fax 212 353.3306 ASSOCIATES INC.

January 16, 2002

Mr. Donald Santo NYC School Construction Authority 30-30 Thomson Avenue Long Island City, NY

Ref: I.S. 89-M 201 Warren Street, Manhattan SCAjob#:M089-14528

Deal’ Mr. Siuilo;

ATC Associates, Inc. provided project and air monitoring services at I.S. 89-M located at 201 Warren Street, Manh.attan, New York. NYC SCA retained and provided Air Tech Lab. Corp, with tire scope of work to conduct the clean up services.

Pliase 1 from: 11/26/01 to; 11/29/01

ATC Associates and SCA lEH field representatives monitored the clean up activities. Upon satisfactory visual inspection, tlie NYC SCA requested ATC to collect PCM air samples throughout the school. The air .samples were analyzed by Phase Contrast Microscopy (PCM) following all applicable Federal, State, and NYC rules and regulations. The results of these samples show airborne fiber concentrations to be less thair 0.01 fibers per cubic centimeter of air (<0.0l f/cc). Phase n from: 1/3/02 to; 1/10/02

ATC Associates and Air Tech Lab were requested by the NYC SCA to perform a clean up following the cleaning of the ventilation system. Air Tech Lab perfonned an intensive clean up of visible dust utilizing wet wipe methods and Hepa vacuumed the 1st, 2nd, 3rd, 4th and Sth floors and 6th floor mechanical and boiler room. A final visual inspection was performed by ATC, SCA field representatives. ’Hie findings determined that the areas were suitable for mi- testing. On the same day an additional visual inspection was perfonned by an UFT representative. ATC Associates collected a total of 50 air samples throughout the school utilizing aggressive methods. The analysis was perfonned in strict conformance with the methodology of the AHBRA Pinal Rule (40 CFRPart 763, October 30'", 1987).

CITY_21MC100_010318483

NYC-WTC_000420356

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420356Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →