TEM analysis, P.S. 89M, lab ID T02-01-002

Machine-extracted title · confidence 48%

TEM asbestos analysis results for PS 89M project, AHERA methodology.

NYC-WTC_000420327–000420333
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: New York Environmental PROJECT: P S. 89M ATHENICA LABORATORY ID #: T02-01-002 DATE OF REPORT: 01/11/02 B n>l.sGRvicssiNC. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS. 01/11/02 TM. (7U} 7M-MW FILTER TYPE: M CE. EFFECTIVE FILTER AREA (mm’): 385 fax. (7U) 78a-wa5 AVERAGE G.O. AREA (mm’): 0.009936

LABORATORY RESULTS

CLIENT LAB. ID IjOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPIIIB. 0‘) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST VZED ZED (structJcm’) AIR CONC. FILTER FOR FOR CIIRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECin- (str./mm’) 0.5:SS<5pm A-19 T02-01- 2"^ floor hall o/s 1800 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-022 room 226 A-20 T02-01- 2"^ floor in stair 1800 5 0.0497 0.0043 0.0086 40.26 0.0086 <0.0043 Chi>s. NA 002-023 #2 A-21 T02-01- 1“* floor hall o/s 1809 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-024 room 127 A-22 T02-01- In cafeteria 1809 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-025 A-23 T02-01- 1* floor hall o/s 1818 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-026 stair #3 A-24 T02-0I- 1** floor in stair 1818 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-027 #3

ANALYST LABORATORY DIRECTOR

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Alhenica Environmental Services Inc. (rVESX is responsible only for information pertaining to samples taken by its employees K Air sampling cassettes will be stored for sixty (60) days. .AES Inc., should be notified within this lime frame for a true duplicate anaivsis I If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided b> the client Under these circumstances, the air concentration data is S supplied solely for l6e convenience of the client. o The report relates only to items tested This report must not be used to claim product endorsement by N VL.AI’ or am other agency of the L' S. Government Test reports mav not be reproduced o e.xcepi in full and with prior approval of AES Inc o The liability of Alhenica Environmental Services Inc with respect Io the services charged, shall in no event exceed llie amount of the Invoice I o o co 4 CO

NYC-WTC_000420330

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420330Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000420310

TEM results for NYC PS 89M asbestos sampling with AHERA method.

Similar indexed content

NYC-WTC_000420303

TEM analysis report for airborne asbestos at P.S. 89M; AHERA methodology.

Similar indexed content

Compare copies and versions →