NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗AMBIENT AIR SAMPLING REPORT for Rector Street site; sampling dates in Sept/Oct 2001.
NYC-WTC_000419770–000420230OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC ASSOCIATES INC. - TEM ANALYSIS LAB GROUP #: 5574 - 09/22/01
Filter Type MCE 25 mm Operator Lab Sample No. 59647
Client Spl. No. T30 Filter Area 385 mm"2
Grid 1.U. y Disk No. Instrument I.D. EM 10 CRX (GO) Area 0.01124 mm"2 Comments Screen Magnification 16,400X
Arc. Voltage 80 kV No. Go to be Analyzed e ( 4.721 Struct Corspd. to 70 s/mm"2.)
I.D. of Structure EDS GO. Structure structure Type Length N or,/ (Nonasb. No. ,0.5 um No Coord. F B C M < 5um > 5um • Chrys. Y Amphibole P Nonasb. Arabi6•/ ND Elements)
1
IS
U
I I
r1
P
-. ..___. .__ -_ -. _ cl .o an nnrenaaf ad anertrn - — rnoto No. tirom I II] u a awe — containing samples) I rid acceptance: structures up to 70s lrhm (1st 4) <5O%untheoIved filt.er, overlapped or folded Street. = 3 0.5um & > 5:1 Aspect Ratio <10% particulate coverage >50% coverage Totals squares N= Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid <5% holes or opaque areas F H l: M Positive diffraction pattern properties conforming to laboratory Identification criteria observed. - Unused portion For ehrynotile: 0.79nm apaein[ for (020) reflections, of filter Chrysotile 0.59nm pacing fur Lhe layer line repeat. streaking Avoided portion of (110) and (190) reflec Lions. f filter For amphlb.iea: 0.59ar layer line repeat, and spprox. Portion of filter (2mm side) 9.5 ratio of non—t►mn d layer Line spot spacing to subject to Amphibole axaminstion layer line re Pest distance (0.59nm). EDs spectrum conforming to laboratory AMPHIBOLES Ambiguous Identification criteria observed. F= Single Fiber (1-9 intersections = f-3 fibers) Ainosite B= Bundle >3 fibers <1 fiber diameter apart) 25mm flltnr Crocidolite Non —asbestos C= Cluster (>9 Intersections) Matrix - stopping Hulas; Anthophyllite NSD= No strictures Detected >50 s/O.O. or In Iat.4 C.O. Tremolite Non —Identified ACtinolite L•\DATA\PRIVATE\MIKEC\CAD0\TEM9 9/22/98
CITY 21MC100 004915967
NYC-WTC 000419913
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329958
Summary and conclusion of TEM results for Man Tech project.
11 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104321
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
14 shared non-person entities · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
11 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237252
Laboratory report documenting transmission electron microscopy analysis of air samples from floors 12 and 14 at 40 Rector Street.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237472
Laboratory report documenting asbestos fiber analysis by TEM for an air sample from 40 Rector Street collected on October 23, 2001.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237385
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105975
Summary of transmission electron microscopy results for asbestos samples from 250 Broadway dated September 16, 2001.
6 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174866
Laboratory data sheet documenting asbestos fiber counts from air samples collected on floors 15 through 17.
5 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237327
Laboratory report page containing specific air volume and sample identification data for transmission electron microscopy asbestos fiber analysis at 40 Rector Street.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174896
Laboratory report detailing asbestos fiber analysis by TEM for samples from floors 16-18 at 40 Rector Street collected October 19, 2001.
5 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000188668
Laboratory report documenting transmission electron microscopy analysis of asbestos samples collected from a New York City Department of Education site in October 2001.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270468
TEM analysis of NSHS sample 61334; includes structure ID and EDS data.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244454
TEM analysis with grid, structure IDs and EDS for NSHS site.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270895
TEM analysis data for sample 62362, Oct 2001, listing structure and EDS results.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174874
Laboratory report detailing transmission electron microscopy analysis of a sample for asbestos fibers dated September 28, 2001.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270781
TEM analysis details for lab sample 62065 (duplicate entry), instrument and area data.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
Similar indexed content
Summary and conclusion of TEM results for Man Tech project.
Similar indexed content
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
Similar indexed content
NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
Similar indexed content
NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
Similar indexed content