NYC Response Asbestos Air Sampling Resuits for Staten island Landfill Sampling Date and Time 6/14/20020700 to 06/15/02 0601 Date VaSidatioii Date; 06/18/2002

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc 0.5ti - 5p 5!4 S/mm" S~f/CC‘* 06/14/02 LF05248 P-1 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/14/02 LF05249 P-2 1221.70 Air <7.0 <0.002 0 0 <13.12 <0.0041 06/14/02 LF05250 P-3 123.50 Air <7.0 <0.022 0 0 <7.87 <0.0245 06/14/02 LF05251 P-4 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/14/02 LF05252 P-5 680.20 Air <7.0 <0.004 0 0 <7.87 <0.0045 06/14/02 LF05253 P-6 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/14/02 LF05255 P-8 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/14/02 LF05256 W-12A 1368.00 Air 10.19 0.003 0 0 <15.75 <0.0044 06/14/02 LF05257 W-12B 1153.80 Air <7.0 <0.002 0 0 <13.12 <0.0044 06/14/02 LF05258 T-15 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/14/02 LF05259 T-16 1296.00 Air 20.38 0.006 0 0 <15.75 <0.0047 06/14/02 LF05260 0-17 1623.60 Air 10.19 0.002 0 0 <19.69 <0.0047 06/14/02 LF05262 0-19 444.60 Air 7.64 0.007 0 0 <7.87 <0.0068 06/14/02 LF05263 MPHS-20 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/14/02 LF05264 TS-21 2296.80 Air <7.0 <0.001 0 0 <19.69 <0.0033 06/14/02 LF05265 PLNT2-22 2028.60 Air <7.0 <0.001 0 0 <19.69 <0.0037 06/14/02 LF05266 Lot Blank 0.00 Air <7.0 n/a NA(^> NA® NA(=^> NA® 06/14/02 LF05267 Trip Blank 0.00 Air <7.0 n/a NA'"> NA'2> NA'2> NA®

Please note that samples for locations TS-21 and PLNT2-22 ran for over 20 hours No sample was submitted for location P-7 and O-18 due to flow fault

Key: * Some sample volume (liters) are below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile **** Actinolite *****Amosite NA <’> - Not analyzed due to overloading of particulates NA - Not analyzed for TEM NA - Not analyzed due to wet filter n/a - Not applicable NR - Not requested NS - Sample not submitted R - Sample data rejected due to no sample volume NC - Sample not collected O NS - Sample not submitted H NiOSH 740S: Fiber Afiaiysis of Air samples via NiOSH 7400, Revision 3, issue 2, 8/15/94 Asbestos Fiber Analysis by Transmission Eiectron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) to Standard criteria: EPA 40CFR Part 763 {AHERA):0.01 tiber/cc (PCM), 70 S/mm’, volume 1200 L, for 25 mm filter (TEM) S O o o I Ln o o [.J

Ui co co [.J

NYC-WTC_000419599

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000419599Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →