NYC Emergency Response Asbestos Air Sampling Results for Staten island Landfill Sampling Date and Time; 10/16/01 0630 to 2000

PGM by NiOSH 7400 TEM ( AHERA) Sampiing Sattipling Sattiple f/mm“ f/cc Structures (#) S/mm“ S~f/cc’ Date Sample No. Location Volume Matrix Q.5-5ti >5ii

10/16/01 03301 P Loc # 1 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03302 P Loc # 2 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03303 P Loc # 3 720 Air <7.0 <0.004 p. 0 8.89 0.0048 10/16/01 03304 P Loc # 4 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03305 P Loc # 5 790 Air <7.0 <0.004 0 0 <10.00 <0.0049 10/16/01 03306 P Loc # 6 720 Air 7.01 <0.004 0 0 <8.89 <0.0048 10/16/01 03307 P Loc # 7 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03308 P Loc # 8 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03309 S Loc # 9A 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03310 S Loc # 9B 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03311 S Loc # 9C 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 10/16/01 03312 3 Loc# 10 A Air _OST SAMP E 10/16/01 03313 3 Loc# 10 B 600 Air <7.0 <0.004 p. 0 7.27 0.0047 10/16/01 03314 W Loc #11 720 Air 16.56 0.009 0 0 <8.89 <0.0048 10/16/01 03315 W Loc #12 720 Air 12.74 0.007 10“ 4** 124.44 0.0665 10/16/01 03316 BLOC# 13 720 Air 8.92 0.005 0 0 <8.89 <0.0048 10/16/01 03317 BLOC# 14 720 Air <7.0 <0.004 1 0 8.89 0.0048 coc# 04636 Chrysotile; no other types of asbestos were detected.

NS: Not sampled AF/ANF: Asbestos fibers/Non asbestos fibers Sample volume is below recommended limit of the method: ‘Structure (S) roughly equivalent to fiber (f) NA: not analyzed due to overloading of particulates NC: Denotes not calculated due to no sample volume.

NiOSH 7400; Fiber Analysis of Air sampies via NIOSH 7400, Revision 3, issue 2, 8/15/94 Asbestos Fiber Analysis by Transmission Electron Microscopy {TEM) ERA 40CFR Part 763 (AHERA) Standard criteria: ERA 40CFR Part 763 (AHERA); 0,01 fiber/cc (PCM), 70 S/mm', volume 1200 L, for 25 mm filter (TEM)

ERT: 10/18/01 9:50 AM

O H

to S o o o I Ln o o to Ui co

Cn

NYC-WTC_000419576

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000419576Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →