Influent: OCDD, 1234678-HpCDD,, and OCDF were detected in the combined influent, resulting in a TEQ of 15.5 pg/L.

Effluent: OCDD and 1234678-HpCDF were detected in the final effluent, with a TEQ of 8 pg/L.

Compound Manhattan Influent * Effluent 1 Rector St. Pumping Station ‘ (pg/L) (pg/L) Runoff^ (pgA.) (pgA.) 1234678-HpCDD 14.6* 29.7 J 14.6* 530.58 JK OCDD 103 176 38..9 5547.62 J

1234678-HpCDF ND 14.2 J 6.3 J 304.09JK OCDF ND 30 J 13.8* 392.70 J

Total HpCDDs ND 29.7 ND _________ Total HpCDFs ND 21.9 ND TEQ3 8.5 15.5 8.0 122 TEQ (include EMPC)" 8.6 15.6 8.0 ND - Non Detect * Reported as ND with an Estimated Maximum Possible Concentration (EMPC) for this compound 1 Paradigm Analytical (REACT contract) 2 Axys Analytical (NYSDEC contract). Blank corrected. 3 ND (including those not shown) = F? of Detection Limit

PCBs (Aroclors):

Pumping Station Not Detected Influent: Not Detected Effluent: Not Detected

BODS (mg/L): Pumping Station 120 Influent: 210 Effluent: 38 % Removal 82

PAHs: Permit limits for PAHs and semi-volatiles do not exist. Levels were elevated in the pumping station sample and the influent. PAHs were not detected in the effluent.

Pumping Station (ug/L) Napthalene (5.8); 2- methyl napthalene (10); 1-methyl napthalene (6.7); biphenyl (1.5); 2,6- dimethylnapthalene (7.9); 2,3,5-trimethylnapthalene (4.5).

CITY_21MC100_0 02647453

NYC-WTC_000419336

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000419336Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000443590

Preliminary data for WTC site sampling; PCB/PAH/metals analyses and locations.

Similar indexed content

Compare copies and versions →