ATC TEM asbestos analysis report, Trinity Place

Machine-extracted title · confidence 49%

ATC TEM asbestos results from Trinity Place project; AHERA method.

NYC-WTC_000418929–000418936
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Associates I 04 East 25 Street, New York, NY 10010 Phone:(212)353-8280 Fax:(212) 353-8306

Attn; Mr. Bernard Orlan Received: 2/13/02 4:15:00 PM N.Y.C. Board of Education 28-11 Queens Plaza North ATC Group#: 6668 Long Island City, NY 11101 .Analysis Date: 2/13/02 Fa.v: (212)475-4122 Phone: (212) 477-8941 Project; H.S. Of Economics And Finance, 8th Floor 100 Trinity Place, New York, NY

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non ‘^^’bestos Striicturei' Sensitivity Concentration Stiiitple k'oliiine Analyzed Ash T'yP‘‘(5) O.Sfi-5 5ft (S/cc) (S/mm-) (S/cc) Notes 04 1805.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 6668 -1

05 1805.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 6668 -2

06 1814.50 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 6668 -3

07 1824.00 O.0450 ' 0 None Detected 0 0 0.0047 <22.24 <0.0047 6668 -4

08 1843.00 0.0450 0 None Detected 0 0 0.0046 <22.24 <0.0046 6668 -5

09 1862.00 .0.0450 0 None Detected 0 0 0.0046 <22.24 <0.0046 6668 -6

10 1871.50 0.0450 0 None Detected 0 0 0.0046 <22.24 <0.0046 6668 -7

ROMAN PEYSAl^OV MICHAEL A. GORYCKl, Ph.D.

Analyzed by: Approved by.

Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data repotted in structures/mm" This report may not be reproduced, except in lull, without written approval by ATC Associates inc. This report may not be used to claim product endorsement by NVLAP or any other agency o( the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.

Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879

CITY_21MC100_010190683

NYC-WTC_0004 18929

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418929Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418940

Analytical TEM asbestos results for H.S. Trinity Place 9th Floor samples.

Similar indexed content

Compare copies and versions →