associated with exposures that are above a ievei of heaith concern.

A7. QUALITY OBJECTIVES AND CRITERIA FOR MEASUREMENT DATA

USEPA has developed a seven-step Data Quality Objectives (DOO) procedure that is designed to ensure that sampling and analysis plans are carefully thought out and that the results of the effort will be adequate to meet the basic objectives of the program. Application of this seven step procedure to each of the three main objectives of this project are presented below.

FIRST OBJECTIVE: Personal Air Monitor vs Stationary Air Monitor

Step 1. State the Problem

The primary issue to be addressed is that asbestos levels in air collected using stationary air monitors located at outside (ambient) locations and in the central living space of apartments or occupied offices may not accurately represent exposures of people engaged in routine or special activities in locations where asbestos or other contaminants associated with the WTC collapse may be released in to the air from debris or dust.

Step 2. Identify the Decision

The decision to be made is whether stationary air monitors can be used to evaluate exposure and risk to residents from airborne asbestos in businesses and apartments in the vicinity of the WTC, or whether personal air sampling should be used in addition to or in place of stationary air monitors.

Step 3. Identify Inputs to the Decision

Data needed to achieve this objective consist of accurate and reiiabie measurements of asbestos ieveis in the breathing zone of peopie engaged in routine or speciai activities in businesses and/or apartments, paired with accurate and reiiabie measurements of asbestos ieveis in air coiiected using a stationary air monitor located in the main living area or workplace. Measurements of asbestos levels in breathing zone air will be collected using personal air monitors.

The number of paired samples needed for each routine or special activity that is investigated is difficult to judge, since it is expected that there could be wide variations between locations in the levels of asbestos in source material (debris or dust), and in c CD the amount of each source material suspended in air by the activity. Thus, the range of E 3 concentration and risk estimates based on either personal or stationary air samples o o could vary substantially from case to case. In general, when variability is wide, more Q samples are needed to support risk management decisions. The objective of this effort TO ■c is to identify a variety of relevant exposure categories (i.e. apartments, apartment co co o co Q_ lobbies, commercial businesses, etc) and evaluate a representative number sites (8-12) o o Z o 3 o 0. o' O) O 6 z CITY_21MC100_008907100 z

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418635Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →