Allan Goldberg - Nyc-wtc sampling plan v2.doc Page 8 i

A7. QUALITY OBJECTIVES AND CRITERIA FOR MEASUREMENT DA 1 a

USEPA has developed a seven-step Data Quality Objectives (DQO) procedure that is iic.avnec; . ensure that sampling and analysis plans are carefully thought out and that the results ofuie effort will be adequate to meet the basic objectives of the program. Application of thus seven step procedure to each of the three main objectives of this project are presented below.

FIRST OBJECTIVE: Personal Air Monitor vs Stationary Air Monitor

Step I. State the Problem

The primary issue to be addressed i.s that asbestos levels in air collected using stationarv :;ir monitors located at outside (ambient) locations and in the central living space of apartment.-; un­ occupied offices may not accurately represent exposures of people engaged in routine or .;.,eci;.i activirie.s in locations where asbe.sto.s or other contaminants associated with the WTC collapse may be released in to the air from debris or dust.

Step 2. Identify the Deeision

The decision to be made is whether stationary air monitors can be used to evaluate exposure and risk to residents from airborne asbestos in businesses and apartments in the vicinity of the WT(\ or whether personal air sampling should be used in addition to or in place of stationary air monitors.

Step 3. Identify Inputs to the Deeision

Data needed to achieve this objective consist of accurate and reliable measurements of asbestos levels in the breathing zone of people engaged in routine or special activities in businesses anci/or apartments, paired with accurate and reliable measurements of asbestos levels in air collected using a stationary air monitor located in the main living area or workplace. Measurements of asbestos levels in breathing zone air will be collected using personal air monitors.

The number of paired sample.s needed for each routine or special activity that i.s investigated is difficult to judge, since it i.s expected that there could be wide variations between locaiiori.s m me levels of asbestos in source material (debiTs or dust), and in the amount of each source material suspended in air by the activity. Thus, the range of concentration and risk estimates based on either personal or stationary air samples could vary substantially from case to case. In general. when variability is wide, more samples are needed to support risk management decisions. I’lie objective of this effort is to identify a variety of relevant exposure categories (i.e. apartments. apartment lobbies, commercial businesses, etc) and evaluate a representative number sires (8-12) within each of these categories. If specific conditions associated with hazardotrs exposure.s are identified, this information can be communicated to the public and practical risk management decisions can be implemented (where necessary) to mitigate or abate unacceptable risks.

NYC-WTC_000241752

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241752Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →