NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
18 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗Draft NYC DOH environmental monitoring document relating to WTC collapse exposure fibers.
NYC-WTC_000418628–000418684OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LOD =95%UCL(0) * Af / (N * Ag * V)
where:
95% UCL(O) = 95% upper confidence limit on an observed count of zero Af = effective area of the filter N = Number of grid openings or fields counted Ag = area of a grid opening or a field V = volume of air drawn through the filter
The values of 95% UCL(O) are 5.5 for PCM (NIOSH 7400) and 3.0 for TEM OSO 10312). Assuming that Af and Ag are fixed, there are then two variables which may be controlled to achieve a required LOD:
V (Air volume) N (Number of grids or fields counted)
Air volume is in turn a function of two independent variables: flow rate and sampling duration. Thus, once a target volume is known, any combination of flow rate and sampling time that achieves that volume will be acceptable (assuming the flow rates are within the recommended range of 0.5 to 10 L/min).
The second variable (number of TEM grids or PCM fields counted) is an important determinant of analytical cost. For the purposes of these calculations, a value of 50 TEM grids and 100 PCM fields was assumed. Sensitivity can be increased by counting more, but this become prohibitive if needed on many filters. Q
H Based n these inputs, the volume of air needed to achieve the target detection limits for each scenario are as follows: S o I—i o Target Volume (L) o Io PCM Method TEM Method o co Activity o Routine 4,870 84,200 Cleaning 40 690 Restoration 0.8 14 Construction 4.0 70
NYC-WTC_000418684
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
18 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
19 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
19 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
19 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
18 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
19 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
19 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
19 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442318
Chain-of-custody outlining indoor and dust sampling protocol for Lower Manhattan residences.
11 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
14 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436633
Protocol overview for indoor/dust sampling across 30 Lower Manhattan buildings, Feb 2002.
11 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241745
Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.
18 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000320385
Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
Similarity score 0.934 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
Similarity score 0.931 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similarity score 0.931 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similarity score 0.931 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418482
WTC background study interim final report prepared for FEMA and EPA contractors.
Similarity score 0.930 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362205
SOP validation study references and definitions for asbestos Part 763 sections.
Similarity score 0.928 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similar indexed content
NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
Similar indexed content
NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
Similar indexed content
NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similar indexed content
NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similar indexed content