Asbestos SOP validation references, Part 763, 1990s

Machine-extracted title · confidence 43%

SOP validation study references and definitions for asbestos Part 763 sections.

NYC-WTC_000362205–000362234
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Protection Agency Pt. 763, Subpt. E. App. A

TABLE 1--NUMDER OF 200 MESH EM GRID OPENINGS <0.0057 MM^) THAT NEED TO BE ANALYZED TO MAINTAIN SENSITIVITY OF 0.005 STRUCTURES/CC BASED ON VOLUME AND EFFECTIVE FILTER AREA

Effective Filter Area Effective Fitter Area 385sqmm 855 SQ mm Volume fitters) # of qrid openirxjs 560 24 1.250 24 600 23 1,300 23 700 19 1.400 21 800 17 1.600 19 900 15 1,800 17 1.000 14 2.000 15 1,100 12 2.200 14 I 1,200 1 1 2,400 13 I 1,300 10 2,600 12 Recommended 1,400 10 2,800 1 1 1 Volume 1,500 9 3,000 10 I Range 1,600 8 3.200 9 Recommended 1 1,700 8 3,400 9 Volume _____ L_ 1,800 6 3,600 8 Range 1,900 7 3.800 8 I 2,000 7 4,000 8 I 2.100 6 4,200 7 2,200 6 4,400 7 2,300 6 4.600 7 2,400 6 4.800 6 2,500 5 s.ooo 6 2,600 5 5.200 6 2,700 5 5.400 6 2,800 5 5.600 5 2,900 5 5.800 5 3,000 5 6,000 5 3,100 6,200 5 3,200 6,400 5 3,300 6,600 5 3,400 6,800 4 3,500 7.000 4 3,600 7.200 4 3.700 7,400 4 3.800 7.600

Note minimum voiumes required: 25 mm 560 liters 37 mm : 1250 liters

Finer diameter or 25 mm - effective area of 385 sq mm Finer diameter of 37 mm « effective area of 855 sq mm

20. Ensure that the sampler is turned up­ 22. Ensure that the samples are stored in a right before interrupting the pump flow. secure and representative location. 21. Check that all samples are clearly la­ 23. Do not change containers if portions of beled and that all pertinent information has these filters are taken for other purposes. been enclosed before transfer of the samples 24. A summary of Sample Data Quality Ob­ to the laboratory. jectives is shown in the following Table IL

673

CITY_21MC100_002846544

NYC-WTC_000362229

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362229Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000442707

Pallet of Part 763 asbestos-related standard references and definitions.

Similar indexed content

Compare copies and versions →