Upon receipt, the samples will be given to the laboratory sample custodian. The coolers will be opened and the contents inspected. Chain-of custody forms will be reviewed for completeness, and samples will be logged and assigned a unique laboratory sample number. Any discrepancies or abnormalities in samples will be noted and the Project Director will be promptly notified.

Record Keeping

Chain-of-custody will be maintained until final disposition of the samples by the laboratory and acceptance of analytical results by NYC. One copy of the chain-of- custody will be kept by field personnel.

Following completion of the project, the NYC Department of Health or a designated representative will consolidate and maintain all original log books, field data sheets, analytical data packages and reports, and any other information required to document and support the findings of the investigation.

B4. ANALYTICAL METHODS REQUIREMENTS

The Appendix B included here provides the names of the SOPs for each analytical method used in this project.

Air and Dust Samples

As discussed above, all air and dust samples collected during this study will be analyzed using both PCM and TEM methods.

Direct vs Indirect Preparation Methods

For both TEM and PCM, two alternative approaches are available: "direct" and "indirect" analysis. In direct analysis, the sample is prepared with minimal handling, generally by placing the test material directly under the microscope for examination. However, this approach may sometimes be inadequate because a) the fibers are accompanied by an excessive level of non-asbestos material, or b) the concentration of asbestos fibers is either too low or too high for reliable quantification. In these cases, an indirect approach may be used. In the indirect method, the sample is generally diluted, concentrated, and/or treated to remove interferences, such that the asbestos fibers can be more reliably quantified. However, because indirect preparation steps may alter fiber morphology and/or may alter fiber recovery, indirect sampling may introduce uncertainty c into the results. CD E 3 o o For the purposes of this study, direct preparations are strongiy preferred for aii air fiiters, Q and a direct preparation wiii be made and examined for aii air sampies. When reiiabie TO ■c fiber counts cannot be obtained for one or both methods due to interfering materials, an co o co Q_ indirect preparation will be made and the indirect preparation will be re-analyzed by both o o Z o 3 o 0. o' O) O 6 z CITY_21MC100_008907116 z

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418651Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →