Scenario 4: Sampling During Exterior Cleanup Activities

Sites will be selected for inclusion in this test scenario based on the results of previous solid media and ambient air sampling results. One area will be selected where debris and/or dust does not contain visible fiber and where PLM and/or Infrared analyses do not reveal the presence of asbestos material. Two areas will be selected where fibrous dust or debris is visible and/or where PLM analysis reveals the presence of asbestos fibers. Sampling will be performed when weather is drier (and hence more likely to release dust and fibers). In addition. Project managers may direct that a second (optional) sample be collected in wet weather by way of comparison. In order to help reduce variability between sites, the same cleanup or remediation tasks will be used at all locations (with appropriate decontamination between locations).

Because of the possibility that outside restoration activities might lead to increased exposure to asbestos fibers in air, this activity will be performed by trained staff or contractors with adequate health and safety training and wearing adequate PPE.

Stationary air monitors will be used to collect ambient air samples at two locations: either 5 meters upwind and 5 meters downwind of the restoration area, or the upwind and downwind perimeter of the property (whichever is closer). The direction and speed of the wind will be recorded throughout the restoration event. The equipment operator will wear a personal air sampling pump. Flow rate for both the stationary and personal air pumps will be approximately equal and will be sufficient to collect the minimum target volume specified in Appendix G (70 L), and the sampling durations will also be equal (about 1 hour).

In order to help quantify the impact of the restoration activity on asbestos levels in ambient air, the down-wind stationary air monitor will also be used to collect a pre-activity and a post activity sample as well as a sample during the activity. Both the pre- and the post activity samples will be at a flow rate adequate to yield a minimum volume of 1200 L, collected over a sampling duration of about 3 hours. This sampling scheme is summarized in the following example schedule:

Minimum Target Volume (L) Activity Example Personal Sampler Stationary Monitor Clock time Pre-sampling 8:00-11:00 1200 Restoration 11:30-12:30 70 70 activity Post activity 1:00-4:00 1200 c CD A downwind aerosol monitor will also be used to monitor dust generation before, during E3 o and after the simulated or actual restoration activity. o Q TO One dust or debris sample will be collected from each restoration location before activity co ■c CD o Q_ occurs. This will be accomplished by collecting a 5 point composite (grab samples) of CO

o o Z o 3 o 0. o' O) O 6 z CITY_21MC100_008907111 z

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418646Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →