Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ug/M^ = microgram per cubic meter
ND = not detected
NA = not Applicable
% = Percent
= Less Than
= Less Than or Equal To
= Metals scan also included; Aluminum, Chromium, Mangcnesc, Molybdenum, Strontium, and Nickel.
Analytical Method for total dust is based on NIOSH 0600
Analytical Method for silica is based on OSHA ID142 and NIOSH 7500
Analytical Method for metals is based on OSHA ID 125G
= Sample result based on analytical method NIOSH 7400. This method utilizes Phase Contrast Microscopy
(PCM) which counts ALL FIBERS longer than 5 microns in length and have a length to width ratio equal to or
greater than 3:1.
= Sample result based on analytical method NIOSH 7402. This method utilizes Transmission Electron
Microscopy (TEM) to identify and quantify asbestos fibers present.
’ = The Ceiling Limit for carbon monoxide is to be measured over a 5 minute sample.
= Results may include soluble non-sulfuric acid sulfur compounds
CITY_21MC100_0 06654001
NYC-WTC_000418611
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000418611Source: NYC Law Department, mirrored locally
Minutes from New York State Department of Health exposure monitoring activities at the World Trade Center site on October 16, 2001, recording asbestos levels for FDNY teams.